TtpTmLossRateRange4

Measurement ID
14304
Measurement Group
TTP Performance
Measurement Type
Duration
Measurement Dimension
Arrayed (by TTP ID)
Description
The duration of TTP Loss Percent Range4.
Collection Interval
5 min
Peg Condition
When the DRL changes a local TTG's Current Loss Percent value, it shall:
  • Save the time of the event in the TTG's RT-DB record called "Loss Start Time"
  • Save the new Current Loss Percent value in the TTG's RT-DB record
  • If the TTG's old Current Loss Percent value is not equal to 0, then:
    • Calculate the duration of time that the TTG's Current Loss Percent was set to the previous value based upon "Loss Start Time" and the current time
    • Determine which TtgTmLossRateRange-X measurement to update based upon the previous TTG Current Loss Percent value and the system-wide LossRateMax1, LossRateMax2, and LossRateMax3 values
    • Update the selected TtgTmLossRateRange-X measurement with the calculated duration of time
Measurement Scope
Site

Recovery

  1. No action required.