Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

31235 - Untrusted Time After Initialization

Alarm Group:
REPL
Description:
After system initialization, the system time has become untrusted probably because NTP has reconfigured improperly, time has been manually changed, the NTP servers are unreachable, etc. There are often accompanying Platform alarms to guide correction. Generally, applications remain running, but time-stamped data is likely incorrect, reports may be negatively affected, some behavior may be improper, etc.
Severity:
Critical
Instance:
May include AlarmLocation, AlarmId, AlarmState, AlarmSeverity, and bindVarNamesValueStr
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
comcolUtrustedTimePostInitNotify

Recovery:

  1. Correct NTP configuration.
  2. If the problem persists, it is recommended to contact unresolvable-reference.htm#GUID-DD0927BD-FD0B-4CEB-86E9-98A33C12D4E0.