RxAsnRecvFailed
- Measurement ID
- 9134
- Measurement Group
- Association Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed (per association)
- Description
- The number of times an SCTP/UDP receive attempt failed on the transport. Failure to receive message via SCTP may result in a message being discarded.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented by one each time an SCTP receive fails when the far-end attempted to send data, but the data cannot be received due to an invalid message length.
- Measurement Scope
- NE, Server
Recovery
- This measurement should have a zero value. A non-zero value indicates that the far-end is sending data that is malformed. You can view Association status from the GUI main menu under .
- Look in the event history log from the GUI main menu under for Event ID 19223. Event ID 19223 gives more information about what caused the failure.
- Try to bring the sockets back into alignment by manually Disabling and Enabling the association.
- It is recommended to contact My Oracle Support for assistance if needed.