RxAsnRecvFailed

Measurement ID
9134
Measurement Group
Association Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (per association)
Description
The number of times an SCTP/UDP receive attempt failed on the transport. Failure to receive message via SCTP may result in a message being discarded.
Collection Interval
30 min
Peg Condition
This measurement is incremented by one each time an SCTP receive fails when the far-end attempted to send data, but the data cannot be received due to an invalid message length.
Measurement Scope
NE, Server

Recovery

  1. This measurement should have a zero value. A non-zero value indicates that the far-end is sending data that is malformed. You can view Association status from the GUI main menu under SS7/Sigtran > Maintenance > Associations.
  2. Look in the event history log from the GUI main menu under Alarms & Events > View History for Event ID 19223. Event ID 19223 gives more information about what caused the failure.
  3. Try to bring the sockets back into alignment by manually Disabling and Enabling the association.