Go to primary content
User Data Repository Alarms, KPIs, and Measurements
Release 12.4
E82598-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxAsnM3uaERROR

Measurement ID
9140
Measurement Group
Association Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (per association)
Description
The number of M3UA ERROR messages received on the association. An M3UA ERROR message is sent by the far-end to complain about an invalid M3UA message that it received.
Collection Interval
30 min
Peg Condition
This measurement is incremented by one each time an M3UA ERROR message is received that cannot be mapped to a specific link.
Measurement Scope
NE, Server

Recovery

  1. This measurement will have a value of zero. A non-zero value indicates a problem with M3UA signaling sent by the MP server.
  2. Look for Event ID 19235 from the GUI main menu under Alarms & Events > View History. Event ID19235 provides more information about the receipt of the ERROR message.
  3. If the ERROR reason in Event ID 19235 indicates a problem with the routing context (i.e., error code 0x19), verify that the MP server link set and the SG are configured to agree on the routing context values that each M3UA signaling link uses.
  4. It is recommended to contact My Oracle Support for assistance if needed.