ExNiddDlApnRateExceeded
- Measurement ID
- 13066
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on APN
- Description
- The number of NIDD Downlink Data packets that were rejected because the APN Downlink Rate limit was reached in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an NIDD Downlink Data Delivery packet is rejected by SCEF application as the configured Downlink APN Rate limit was reached.
- Measurement Scope
- Network Element, Place Association
Recovery
- If the pegging of this measurement is unexpectedly high, review the Downlink APN Rate Control configuration.