ExNiddDlApnRateExceeded

Measurement ID
13066
Measurement Group
SCEF NIDD Exception
Measurement Type
Simple
Measurement Dimension
Arrayed on APN
Description
The number of NIDD Downlink Data packets that were rejected because the APN Downlink Rate limit was reached in the given collection interval.
Collection Interval
30 min
Peg Condition
This measurement is incremented each time an NIDD Downlink Data Delivery packet is rejected by SCEF application as the configured Downlink APN Rate limit was reached.
Measurement Scope
Network Element, Place Association

Recovery

  1. If the pegging of this measurement is unexpectedly high, review the Downlink APN Rate Control configuration.