The GatewaySynchronization service sends information from P6 to Primavera Unifier or Oracle Primavera Cloud via Primavera Gateway.
To configure GatewaySynchronization:
- Open the Primavera P6 Administrator.
- In the Configurations drop-down list, select your configuration.
- In the sidebar select Services/Job Services.
- Select GatewaySynchronization.
- In the Interval field, enter the amount of time to wait before running the next available job (in 1d1h1m1s format, specifying only numbers without letters implies milliseconds).
The default value is 10s.
Enter a value between 1s and 24d20h31m23s647.
- In the Concurrent Threads field, enter the number of processes used for this service on this server. A value of 0 indicates that that this job will not run on this server.
The default value is 2.
Enter a value between 0 and 20.
- In the Active Mode field, select true if you want jobs processed continuously until all jobs finish. Select false if you want each job processed according to the Interval.
- In the Timeout for Gateway job completion field, enter the maximum time P6 will wait for a gateway job to be completed before marking its status as failed or timed out.
The default value is 12 minutes.
Enter a value between 1 minute and 2 days.
- In the Interval field, enter the amount of time to wait before running the next available job (in 1d1h1m1s format, specifying only numbers without letters implies milliseconds).