2.3.2.3 Overview of the Automated Site Upgrade Procedure

The information in this section provides a general overview of the automated site upgrade process. Always refer to the application specific upgrade instructions based on each release.

Follow these general steps when performing an automated site upgrade:

  1. Upgrade the NO server group serially (one at a time) to ensure at least one NO is always active to provide OAM&P.
  2. Upgrade the DRNO server group. Note that some products upgrade these first.
  3. Select an SO network element and upgrade it as follows:
    • The SO servers can either be serial or bulk (non-active at once, then active) as specified in General Options.
    • Upgrade the MP servers using desired availability settings. The code uses the following rules (some of which can be specified by the user):
      • Servers are upgraded in parallel as long as the number of active, non-upgrading servers exceeds the user specified minimum availability.
      • Servers can be upgraded serially instead.
      • Servers are upgraded in HA order meaning Spare servers followed by Observer, Stby, and Active. An additional application-level customization allows certain servers to be upgraded last, once the rest of their group has upgraded.
  4. Repeat step 3 until all SO network sites are upgraded (thereby completing upgrade of the entire network).
  5. Accept the upgrade.

Caution:

Contact unresolvable-reference.html#GUID-DCC4D7F0-BD3A-4AB0-84CC-B706FFCEF107 and inform them of your upgrade plans before beginning this or any upgrade procedure. Before upgrading, go to the unresolvable-reference.html#GUID-DCC4D7F0-BD3A-4AB0-84CC-B706FFCEF107 website to acquire the correct upgrade procedure for your product and review any relevant Technical Service Bulletins (TSBs).