3.76.2.1 DxDevTriggMsgAll
- Measurement ID
- 13400
- Measurement Group
- SCEF Device Triggering Performance
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The total number of messages processed by the Device Triggering feature of the SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented on each of these occasions:
- An ingress Device Triggering Diameter message is received
- An ingress Device Triggering HTTP message is received
- A Device Triggering Diameter message is generated and transmitted
- A Device Triggering HTTP message is generated and transmitted
- Measurement Scope
- Network Element, Place Association
Recovery