3.76.8.8 TxNiddCmaEstablishFailure

Measurement ID
13030
Measurement Group
SCEF NIDD Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of Diameter CMR Establishment messages for which a failure was returned by SCEF application in the given collection interval.
Collection Interval
30 min
Peg Condition
This measurement is incremented each time an ingress Diameter CMR message with a Connection-Action value CONNECTION_ESTABLISHMET fails to get processed and is responded with a result code other than 2001.
Measurement Scope
Network Element, Place Association

Recovery

  1. The response message may contain an application/problem+json body describing the details of the problem encountered that failed the request.
    Possible causes may be:
    • The requested NIDD configuration (identifier by the SCS Application Server APN and IMSI) was not found in the SCEF database.