3.7 Flow Control for ENUM queries

An ENUM application can process up to the set Max vENUM TPS limit, above which the MP performs the following actions:
  • Discards the messages.
  • Notifies the client with ENUM error response if the ENUMOPTS option CNGNTFY is TRUE.
  • Raises an event according to the ENUM error response code configured in ENUMOPTS table option CNGRCODE. The allowed values for CNGRCODE option are 5 to 15. The default value of the CNGRCODE is 5 (ENUM_QRY_REFUSED).
  • ENUM error response message due to congestion is paced at a rate of 1 error message per 100 discarded ENUM messages at the application level.
  • Pegs the measurements for total discarded ENUM messages and messages discarded due to congestion at the application level.