3.90.9 EvSctpAdjPToDwn

Measurement ID
9424
Measurement Group
Transport Exception
Measurement Type
Max
Measurement Dimension
Arrayed (per Transport)
Description
The number of times a configured IP Address of an Adjacent Node goes from Available to Unavailable.
Collection Interval
30 min
Peg Condition
Each time reachability to a configured IP address of an Adjacent Node is lost, indicating a fault in the path to that address was detected.
Measurement Scope
NE, Server

Recovery

  1. If all is well, this measurement should have a zero value. A non-zero value indicates a path fault to that address was detected.
  2. Otherwise:
    1. Check the event history log at Main Menu, and then Alarms & Events, and then View History, looking for Event 19409 - Message Rejected by ACL Filtering which provide more details as to the actual cause of the failure.
    2. Verify the Adjacent Node that represents the far-end of the association is configured with the correct address at Main Menu, and then Transport Manager, and then Configuration, and then Adjacent Node.
    3. Verify the IP network connectivity between the MP server and the Adjacent Node's IP address using a ping or traceroute command
  3. It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if needed.