3.60.2 PcaOcDrop
- Measurement ID
 - 11463
 - Measurement Group
 - P-DRA Diameter Exception
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Single
 - Description
 - The number of PCA originated messages rejected by DA-MP overload control..
 - Collection Interval
 - 5 min
 - Peg Condition
 - The measurement is pegged each time a PCA-generated RAR is rejected due to DRL queue full or DA-MP OC.
 - Measurement Scope
 - All
 
Recovery
- This measurement indicates that a DA-MP may be experiencing congestion. Additional processing capacity at the PCA DA-MP may be needed.