3.60.2 PcaOcDrop

Measurement ID
11463
Measurement Group
P-DRA Diameter Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of PCA originated messages rejected by DA-MP overload control..
Collection Interval
5 min
Peg Condition
The measurement is pegged each time a PCA-generated RAR is rejected due to DRL queue full or DA-MP OC.
Measurement Scope
All

Recovery

  1. This measurement indicates that a DA-MP may be experiencing congestion. Additional processing capacity at the PCA DA-MP may be needed.