3.38.7 RxFabrResolFailCmdcode

Measurement ID
10631
Measurement Group
Full Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Arrayed (by Diameter Application ID)
Description
Number of Request messages received with an unknown Command Code.
Collection Interval
5 min
Peg Condition
For each routing exception where the (Application ID, Command Code) pair in the incoming Request message is not configured.
Measurement Scope
Server Group

Recovery

  1. The currently provisioned Diameter Application IDs can be viewed in the FABR Configuration & Maintenance GUI.

    It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance.