3.54.6 RxGyRoAns2xxxFromPeerPerCmd
- Measurement ID
 - 11370
 - Measurement Group
 - OC-DRA Diameter Usage
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Arrayed (by Diameter Message Command Abbreviation i.e. CCR-I/U/T/E, RAR, UNK-REQ and “Total”)
 - Description
 - The number of Gy/Ro Diameter Credit Control Application Request messages successfully relayed by OC-DRA that received Answers from the peer with a 2xxx (Success) Result-Code value.
 - Collection Interval
 - 5 min
 - Peg Condition
 - Each time OC-DRA receives an Answer from the peer with a successful Result-Code AVP (one containing a value in the range of 2000 – 2999).
                        
Note:
This measurement is pegged twice, once for the Diameter message command abbreviation and once for "Total". - Measurement Scope
 - All
 
Recovery