3.60.12 RxStackEventDiscardedCaFailure
- Measurement ID
 - 10866
 - Measurement Group
 - P-DRA Diameter Exception
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Single
 - Description
 - Number of stack events discarded by ComAgent due to ComAgent failure.
 - Collection Interval
 - 5 min
 - Peg Condition
 - The measurement shall be incremented by one each time a stack event is discarded by ComAgent due to a ComAgent failure as indicated by a returned stack event error code of all available error codes.
 - Measurement Scope
 - All
 
Recovery
- Check ComAgent Event 19832 - Communication Agent Reliable Transaction Failed (refer to the DSR Alarms and KPIs Reference for details about this event) and ComAgent measurements CAHSTxDscrdCongSR, CAHSTxDscrdUnkwnRsrc, and CAHSTxDscrdIntErrSR for detailed error causes.
 - If the problem persists, it is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance.