3.72.17 SbrSlavePollingContinue

Measurement ID
11355
Measurement Group
SBR Binding Performance
Measurement Type
Simple
Measurement Dimension
Single
Description
A count of the number of early binding polling attempts for which the poller was instructed to continue polling.
Collection Interval
5 min
Peg Condition
Each time an Early Binding Slave session polls the Early Binding Master and all of the following conditions are true:
  • The Early Binding Master sessionRef still exists in the binding database and is in the EarlyMaster state.
  • The Early Binding Slave sessionRef still exists in the binding database
  • The Early Binding Master sessionRef has not been in existence for longer than the Maximum Early Binding Lifetime
  • PCRF Pooling is Enabled
Measurement Scope
Network Element, Server Group, Resource Domain, Place, Place Association

Recovery

  1. This measurement gives an indication of the frequency at slave pollers are asked to continue polling. If this value is equal to or higher than the SbrEarlySlaveBindingsCreated, the Early Binding Polling Interval configured in Policy DRA, and then Configuration, and then Network-Wide Options may be set to a duration too short, causing unnecessary polling attempts. If this value is very low relative to the SbrEarlySlaveBindingsCreated, the Early Binding Polling Interval may be set to a duration too long, causing unnecessary latency for slave sessions.
  2. It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729.