3.83.21 SCCPStackQueueFull
- Measurement ID
- 9159
- Measurement Group
- Server SCCP Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of ingress SCCP messages that were discarded because the SCCP Stack Event Queue was full.
- Collection Interval
- 30 min
- Peg Condition
- For each message discarded
- Measurement Scope
- NE, Server
Recovery
- If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the number of MPs in the Network Element may need to be increased.
- If the peak and average for an individual MP are significantly different than other MPs in the same Network Element, then an MP-specific hardware, software, or configuration problem may exist.
- It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if needed.