3.84.10 SCCPStackQueuePeak

Measurement ID
9157
Measurement Group
Server SCCP Performance
Measurement Type
Max
Measurement Dimension
Single
Description
The peak SCCP Stack Event Queue utilization (0-100%) measured during the collection interval. This measurement is primarily intended to assist in evaluating the need for additional MP processing capacity at a Network Element.
Collection Interval
30 min
Peg Condition
The maximum SCCP Stack Event Queue utilization sample taken during the collection interval.
Measurement Scope
NE, Server

Recovery

  1. If both the peak and average measurement for multiple MPs within a Network Element are consistently near the recommended maximum engineered capacity of an MP over several collection intervals, then the number of MPs in the Network Element may need to be increased.
  2. If the peak and average for an individual MP are significantly different than other MPs in the same Network Element, then an MP-specific hardware, software, or configuration problem may exist.
  3. It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if needed.