3.77.4 SCTPAggrQueueFull
- Measurement ID
- 9174
- Measurement Group
- Server M3UA Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of egress messages that were discarded because the number of SCTP messages queued in all SCTP Single Association Writer Queues exceeded a maximum capacity.
- Collection Interval
- 30 min
- Peg Condition
- Each time a SCTP Aggregate Association Writer Queue message is discarded
- Measurement Scope
- NE, Server
Recovery
- An IP network or STP/SG problem may exist preventing SCTP from transmitting messages into the network on multiple Associations at the same pace that messages are being received from the network.
- One or more SCTP Association Writer threads may be experiencing a problem preventing it from processing events from its event queue. Examine the alarm log from GUI main menu under .
- If one or more MPs in a server site have failed, the traffic will be distributed among the remaining MPs in the server site. You can monitor MP server status from .
- The misconfiguration of STP routing may result in too much traffic being distributed to the MP. You can monitor the ingress traffic rate of each MP fromserver site should be receiving approximately the same ingress transactions per second. . Each MP in the
- There may be an insufficient number of MPs configured to handle the network traffic load. You can monitor the ingress traffic rate of each MP from server site is exceeding its capacity. . If all MPs are in a congestion state, then the offered load to the
- If the problem persists, it is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729.