3.91.2 TmTrEnaNotUp
- Measurement ID
 - 9410
 - Measurement Group
 - Transport Performance
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Arrayed (per Transport)
 - Description
 - The number of seconds during the reporting interval during which the transport was in the Enabled administrative state but was not in APP-UP protocol state. When the transport is Enabled, the desired protocol state is APP-UP. This measurement indicates the amount of time during the reporting interval for which the association was not in the desired protocol state.
 - Collection Interval
 - 30 min
 - Peg Condition
 - Time shall be accumulated for this measurement during the collection interval when all of the following are true:
                        
- the association is in the ENABLED administrative state
 - the association is not in the ASP-UP protocol state for M3UA and APP-UP for other Plugins
 
 - Measurement Scope
 - NE, Server
 
Recovery
- If all is well, this measurement should have a zero value. A non-zero value indicates that the MP server has attempted to connect to the Peer IP Address at least once and failed to establish the SCTP connection.
 - Otherwise:
- Association status can be viewed at .
 - Verify that the Adjacent server that represents the far-end of the association is configured with the correct IP address at .
 - Verify that the remote port configured at for the association correctly identifies the port that the SG is listening on for SCTP connections.
 - Verify the IP network connectivity between the MP server and the SG.
 - If the Adjacent Node must be configured to connect to the MP server's IP address and port, verify that the Adjacent Node configuration matches the association configuration at .
 - It is recommended to contact unresolvable-reference.html#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if needed.