3.55.9 TxGyRoCcrUpdateAnsGenPerErrCode
- Measurement ID
 - 11404
 - Measurement Group
 - OC-DRA Diameter Exception
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Arrayed (by 3-digit error code defined in Policy DRA Error Resolution Procedures)
 - Description
 - The number of Gy/Ro Credit-Control-Request messages with the CC-Request-Type AVP set to UPDATE_REQUEST (CCR-U) that OC-DRA abandoned processing due to a failure and generated an Answer response.
 - Collection Interval
 - 5 min
 - Peg Condition
 - Each time OC-DRA abandons the processing of a Gy/Ro Credit-Control-Request message with the CC-Request-Type AVP set to UPDATE_REQUEST (CCR-U) due to a failure and generates an Answer response. Processing failures include the following:
                        
- OC-DRA is Unavailable or Disabled
 - Diameter Protocol Error Detected
 - OC-DRA specific errors due to absence of mandatory Diameter Credit Control Application AVP(s) used for routing
 - Diameter Message Routing failure due to DRL's Request Queue Full
 - Communication Agent Error (i.e., Queue Full)
 - Unexpected SBR Error
 - Online Charging Session not found when required for routing
 
 - Measurement Scope
 - All
 
Recovery
- This measurement represents an exception condition in which Gy/Ro Diameter Credit-Control-Request messages with the CC-Request-Type AVP set to UPDATE_REQUEST (CCR-U) are being received and rejected due to the various reasons stated in “Peg Condition”. A Diameter Answer response including an Error-Message AVP is generated for each Diameter Request message that is rejected.
 - This measurement shows the distribution of Gy/Ro Diameter CCR-U messages that OC-DRA generated a Diameter Answer with error response across the range of 3-digit error codes defined in Policy DRA Error Resolution Procedures to determine the specific cause of failure and resolution using the 3-digit error codes.