3.55.14 TxPcaAnsGenPerErrCode
- Measurement ID
 - 11409
 - Measurement Group
 - OC-DRA Diameter Exception
 - Measurement Type
 - Simple
 - Measurement Dimension
 - Arrayed (by 3-digit error code defined in Policy DRA Error Resolution Procedures and "Total")
 - Description
 - The number of Diameter Request messages that PCA abandoned processing due to a failure and generated an Answer response.
 - Collection Interval
 - 5 min
 - Peg Condition
 - Each time PCA abandons the  processing of a Request message due to a failure and generates an Error Answer  response. Processing failures include the following: 
                        
- A PCA function is Unavailable or Disabled
 - Diameter Protocol Error Detected
 
Note:
This measurement is pegged twice, once for the 3-digit error code and once for "Total." - Measurement Scope
 - All
 
Recovery
- This measurement represents an exception condition in which Diameter Request messages are being received and rejected due to the various reasons stated in “Peg Condition”. A Diameter Answer response including an Error-Message AVP is generated for each Diameter Request message that is rejected.
 - This measurement shows the distribution of Diameter Request messages that PCA generated a Diameter Answer with error response across the range of 3-digit error codes defined in Policy DRA Error Resolution Procedures to determine the specific cause of failure and resolution using the 3-digit error codes.