3.7.61 19905 - Measurement Initialization Failure
- Alarm Group:
- STK
- Description:
- A measurement object failed to initialize.
- Severity:
- Critical
- Instance:
- <measTagName>
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- dbcMeasurementInitializationFailureNotify
- Cause:
-
All Measurements are bound to a specific Measurement ID or Measurement Name defined in the Internal Database. This alarm is raised when Measurement subsystem initialization has failed, which occurs only when the system (or a process) is coming up.
The alarm raises when:
- An application is trying to bind the measurement using an incorrect measurement identifier which does not exist in Database. If you have performed an upgrade or a new installation, contact My Oracle Support for assistance.
- An unauthorized configuration change resulted in inconsistent data.
- Diagnostic Information:
- Note any configuration change made to the system which requires (or caused) a process(or system) restart. Additionally, note alarm instance and any additional information present in alarm's Additional Info section.
Recovery: