3.7.61 19905 - Measurement Initialization Failure

Alarm Group:
STK
Description:
A measurement object failed to initialize.
Severity:
Critical
Instance:
<measTagName>
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
dbcMeasurementInitializationFailureNotify
Cause:

All Measurements are bound to a specific Measurement ID or Measurement Name defined in the Internal Database. This alarm is raised when Measurement subsystem initialization has failed, which occurs only when the system (or a process) is coming up.

The alarm raises when:

  • An application is trying to bind the measurement using an incorrect measurement identifier which does not exist in Database. If you have performed an upgrade or a new installation, contact My Oracle Support for assistance.
  • An unauthorized configuration change resulted in inconsistent data.
Diagnostic Information:
Note any configuration change made to the system which requires (or caused) a process(or system) restart. Additionally, note alarm instance and any additional information present in alarm's Additional Info section.

Recovery:

  1. Measurement subsystem initialization has failed for the specified measurement. If alarm is raised after a configuration change, try to revert back the configuration and restart the process that raised the alarm.