2.9.7 Troubleshooting
The following are the troubleshooting scenarios for TDM support:
- The E1/T1 links do not align
properly
Do the following to troubleshoot:
- Verify that the cable is not faulty.
- Verify the cable connections.
- Verify that the Adax HDC3 card configuration (in QCXfile) is as per the Interface Mapping configuration.
- Ensure that the Adax HDC3 card timing source configuration is correct. In case of SUERM errors, modify the timing source.
- Frequent toggling of the E1/T1
Links
Do the following to troubleshoot:
-
Verify that the point codes associated with the linkset are correct.
- Verify that the link alignment and SLTM timers are correct.
-
-
Adax HDC3 Card is not
detected on a vSTP MP VM
Do the following to troubleshoot:
-
Check that the vSTP MP VM and the Adax HDC3 card are co-located on same host machine.
- Check the Adax HDC3
RPMs.
The following RPMs are required on vSTP MP VM for configuring Adax HDC3 Card:
- Adax-LiS-2.21.8-1-RedHat-6.10-x86-64bit.rpm
- Adax-hdc-1.79-1-RedHat-6.10-x86-64bit-LiS2.21.8-MAJ234.rpm
- Adax-qcx-1.25-1-Linux-x86-64bit.rpm
-
Note:
The vSTP MP VM and the Adax HDC3 card must be co-located on same host machine.