7.3.8.1 Additional Provisioning Rules

Basic input data validation is done using the DCA Framework’s Configuration Data Provisioning GUI. Additional validation is performed during DSA business logic script compilation. If validation fails, the compilation also fails and Event #33309 is raised with appropriate error text. For script compilation, refer to the DCA Programmer’s Guide.

  • If Visited-PLMN-ID and Origin-Realm Consistency Check (VplmnORCst) countermeasure is provisioned in Security_Countermeasure_Config Table, then this table cannot be empty. At least one entry needs be provisioned.
  • The allowable separator for configuring multiple Command-Codes in Command_Codes is semicolon (;).
  • Command-Codes configured in Command_Codes must be in valid Format. Valid Command-Code Range is 0–16777215.
  • A Command-Code can be configured only once for a given Application-ID. No duplicate Command-Code is allowed.