7.3.11 TimeDistChk_MCC_Config Table

This table is used to customize the behavior of Time-Distance Check (TimeDistChk) countermeasure by using the following options.

Table 7-22 TimeDistChk_MCC_Config Fields

Field Description
Source and Destination Node-IDs

Defines the two Node-ID values. Node-ID will be MCC of any given network. Value of MCC_Or_VPLMNID configured in System_Config_Options Table determines that the configured Node-IDs is MCCs.

If MCC_Or_VPLMNID is configured as MCC_Based, then the Node_ID_1 and Node_ID_2 from TimeDistChk_MCC_Config table is treated as MCC values.
Minimum Transition Time Defines the minimum transition time (in minutes) required to move between Node_ID_1 and Node_ID_2.

This table describes the field details for the TimeDistChk_Config Table.

Table 7-23 Field Details for TimeDistChk_MCC_Config

Field Name Unique Mandatory Data Type, Range, and Default Value Description
Node_ID_1 No Yes

Integer

Range: 100-999

Integer: 3 digits

Default: N/A

MCC in digits

MCC_Or_VPLMNID configured in System_Config_Options Table is used to determine configured Node_ID is MCCs.
Node_ID_2 No Yes

Integer

Range: 100-999

Integer: 3 digits

Default: N/A

MCC in digits

MCC_Or_VPLMNID configured in System_Config_Options Table is used to determine configured Node_ID is MCCs.
Minimum_Transition_Time No Yes

Integer

Range: 1–4320

Default: N/A