3.2.1.2 Inserting a supported Diameter application

Use this task to add an application ID in the Diameter message.

Inserting a supported application automatically adds three (3) routing exceptions (Unknown Command Code, No valid Routing Entity Address, and Missing Configured Address Entry) with the Routing Exception Action set to Forward Unchanged.
  1. Click RBAR, and then Configuration, and then Applications.
  2. Click Insert.
  3. From the Application ID list, select the Application ID in the Diameter message.

    Note:

    The application IDs displayed in this list are those created using Diameter, and then Configuration, and then Application IDs.

    Note the Routing Mode field is disabled.

    For more information about each field, see Table 3-1.

    Note:

    The Routing Mode field is disabled.
  4. Perform one of the following actions:
    • Click OK to save the application and return to the RBAR, and then Configuration, and then Applications page.
    • Click Apply to save the application and stay on this page.

      Note:

      If field validations succeed after clicking either OK or Apply, the new application is saved and an informational message about the automatic addition of the routing exceptions appears.
    • Click Cancel to return to the RBAR, and then Configuration, and then Applications page without saving the changes.
    If OK or Apply is clicked and any of the following conditions exist, an error message appears:
    • The Application ID is empty; no value was entered or selected
    • The Application Name or Application ID is not unique; it already exists in the system
    • The entry in any field is not valid (wrong data type or out of the valid range)
    • The maximum number of supported Diameter applications (16) is already defined in the system