Post Installation Database Update Exit Codes

The following table describes all Post Installation Database Update (PostInstallDBSetup utility) exit codes.

Return Code Description (Internal Only) Console Message

0

WSRanking - Successful

SeedSchema - Successful

WFUpgrade - Successful

TaskUpgrade - Successful

Successfully completed WSRanking Utility Execution

Successfully completed SeedSchemaSetup Utility Execution

Successfully completed Workflow Upgrade Utility Execution

Successfully completed Task Upgrade Utility Execution

Post Installation Database Setup execution Completed

1

WSRanking - NA

SeedSchema - Successful

WFUpgrade - Successful

TaskUpgrade - Successful

WSRanking Utility Execution is Not Applicable

Successfully completed SeedSchemaSetup Utility Execution

Successfully completed Workflow Upgrade Utility Execution

Successfully completed Task Upgrade Utility Execution

Post Installation Database Setup execution Completed

2

WSRanking - NA (its RR environment)

SeedSchema - NA

WFUpgrade - NA

TaskUpgrade - NA

RR environments only - none of these utilities are required.

3

WSRanking - Failed

SeedSchema - Not run

WFUpgrade - Not run

TaskUpgrade - Not run

WSRanking Utility Execution failed

Post Installation Database Setup execution failed

4

WSRanking - Successful

SeedSchema - Failed

WFUpgrade - Not run

TaskUpgrade - Not run

Successfully completed WSRanking Utility Execution

SeedSchemaSetup Utility Execution failed

Post Installation Database Setup execution failed

5

WSRanking - NA

SeedSchema - Failed

WFUpgrade - Not run

TaskUpgrade - Not run

WSRanking Utility Execution is Not Applicable

SeedSchemaSetup Utility Execution failed

Post Installation Database Setup execution failed

6

WSRanking - Unknown

SeedSchema - Unknown

WFUpgrade - Unknown

TaskUpgrade - Unknown

Unexpected errors or warnings - review log files.

7

WSRanking - NA

SeedSchema - NA

WFUpgrade - NA

TaskUpgrade - NA

Attempt was made to run against a pre-IP2017 Repository.

8

WSRanking - NA

SeedSchema - NA

WFUpgrade - NA

TaskUpgrade - NA

Attempt was made to run PostInstallDBSetup for a second time for the same version.

9

WSRanking - Successful

SeedSchema - Successful

WFUpgrade - Failed

TaskUpgrade - Not run

Successfully completed WSRanking Utility Execution

Successfully completed SeedSchemaSetup Utility Execution

Error while Workflow upgrade Utility Execution

Post Installation Database Setup execution Completed

10

WSRanking - Successful

SeedSchema - Successful

WFUpgrade - NA

TaskUpgrade - NA

Successfully completed WSRanking Utility Execution

Successfully completed SeedSchemaSetup Utility Execution

Workflow Upgrade Utility Execution is not Applicable

Task Upgrade Utility Execution is not Applicable

Post Installation Database Setup execution Completed

11

WSRanking - NA

SeedSchema - Successful

WFUpgrade - Failed

TaskUpgrade - Not run

WSRanking Utility Execution is Not Applicable

Successfully completed SeedSchemaSetup Utility Execution

Error while Workflow upgrade Utility Execution

Post Installation Database Setup execution Completed

12

WSRanking - NA

SeedSchema - Successful

WFUpgrade - NA

TaskUpgrade - NA

WSRanking Utility Execution is Not Applicable

Successfully completed SeedSchemaSetup Utility Execution

Workflow Upgrade Utility Execution is not Applicable

Task Upgrade Utility Execution is not Applicable

Post Installation Database Setup execution Completed

13

WSRanking - NA

SeedSchema - NA

WFUpgrade - NA

TaskUpgrade - NA

Defer option only—indicates that Schema Generation was successful.

14

WSRanking - NA or Successful

SeedSchema - NA or Successful

WFUpgrade - NA or Successful

TaskUpgrade - Failed

NA

15

WSRanking - NA

SeedSchema - Successful

WFUpgrade - Successful

TaskUpgrade - NA

NA

16

WSRanking - Successful

SeedSchema - Successful

WFUpgrade - Successful

TaskUpgrade - NA

NA

The console outputs a full statement for each of the sub-processes invoked by PostInstallDBSetup. These are in one of the following formats:

  • <Process> is Not Applicable (for example, “WSRanking Utility Execution is Not Applicable”)
  • <Process> Successfully completed (for example, “SeedSchemaSetup Utility Successfully completed”
  • <Process> Failed (for example, “TaskUpgrade Utility Execution Failed”)

An overall assessment is added after all the sub-processes have been listed stating “PostInstallation Database Setup Failed/Succeeded”.