EAI XML Converter Parameters

You can control the location of where you want the temporary EAI XML Converter file generation to occur as well as the threshold by setting two server component parameters as described in the following table. For more information about setting these and other server component parameters, see Siebel System Administration Guide.

Server Component Parameter Name Server Component Type Description

XMLTempFilePath

EAIXMLConvSubsys

Use this parameter to specify the location where you want the temporary XML conversion files generated when EAI XML Converter response size is greater then the size specified in the XMLTempFileSize parameter. By default, if the response size is greater than 50kb, then generation occurs in the SIEBSRVR_ROOT\temp directory.

XMLTempFileSize

EAISubSys

Use this parameter to specify the threshold size for EAI XML Converter method responses. For more information about these methods, see Siebel XML Converter Business Service Comparison.