Optimizer Parameter Set Configuration
The following table describes the recommended parameter value settings for the Optimizer.
Parameter | Recommended Value |
---|---|
Optimizer - Save Interval |
Set this parameter to 15. |
Optimizer - Logging Level |
Set this parameter to 3, unless you want to diagnose a problem. |
Optimizer - Optimize Heuristic |
Set this parameter to 5. Set this parameter higher for more accurate results and lower for faster results. |
Optimizer - Timeout |
Set this parameter to 180. Three hours is generally enough time to find a good solution. |
ABS - Days to Start |
Set this parameter to 1. This parameter controls how many days out the schedule is optimized. Setting this parameter to higher than 5 greatly increases memory usage and is not recommended. |
Month Start Date |
Set this parameter to 1. This parameter is primarily relevant if you use constraints for monthly capacity. |
Week Start Day |
Set this parameter to 1. This parameter is primarily relevant if you use constraints for weekly capacity. |
Optimizer - Glued |
Set this parameter to 120. This parameter is primarily relevant if you use Contract Scheduling during the day instead of batch scheduling overnight. |
Optimizer - Default Priority |
Set this parameter to 3. |
Optimizer - Consider Parts |
Set this parameter to 0. |
Optimizer - Task Excl Cost |
Set this parameter to 500 so that tasks are not deleted from the schedule unless absolutely necessary. |
Optimizer - Hard Latest Start |
Set this parameter to 0. |
Use Assignment Manager |
Set the parameter to 1 if you use skills to restrict candidates. |