Enabling and Configuring Siebel ARM
Enabling and configuring Siebel Application Response Measurement (Siebel ARM) involves setting Siebel ARM parameters on the Siebel Server, as outlined in the following procedure. By default, Siebel ARM is disabled.
Show Advanced
Objects
(alias ShowAdvancedObjects
) is set
to TRUE
for the server component Server Manager (alias
ServerMgr), or click Advanced to view the parameters in a server configuration
view.To enable and configure Siebel ARM on the Siebel Server
Set the parameter
SARM Granularity Level
(aliasSARMLevel
) to a value of 1 or 2 to enable Siebel ARM on the Siebel Server.You can enable Siebel ARM at either the enterprise, Siebel Server, or server component level. For more information about this parameter and its settings, see About Siebel ARM Parameters and Variables.
Set the other Siebel ARM-related parameters to configure the Siebel ARM file characteristics on the Siebel Server.
You can configure Siebel ARM at the Siebel Server or server component level. For more information about these parameters, see About Siebel ARM Parameters and Variables.
For more information about setting Siebel Server parameters using the Server Manager GUI or command-line interface, and for background information about parameter administration, see Siebel System Administration Guide.