3.19.193 70435 - Vstp Dynamic learning Profile Table Full
- Event Group
- vSTP
- Description
-
The dynamic-learning code raises the alarm when the profile count reaches the fixed limit (50K) and clears after aged entries reduce the count. Aging is governed by the configured aging value; a zero/None value prevents the age-removal path. Aging Timer is evaluated in hours.
- Severity
- Major
- Instance
- None
- HA Score
- Normal
- OID
- VstpVlrDynProfileTableFull
Recovery
- Confirm dynamic learning is in use and inspect the profile-table count, learning mode, and configured AgingTimer through approved GUI/MMI procedures.
- Aging can be used to reduce the count. To review or change aging, go to VSTP > Configuration > SFAPP Options. Select the single SFAPP Options row and click Edit. Set Aging Timer to the change-approved value, then click OK or Apply and reopen the row to confirm it saved. The supported values are None or 1–65535; use a non-None value when automatic aging is required.
- If aging is configured, allow the product’s aging process to remove eligible entries and verify the alarm clear once the count falls below the limit.
- If aging is disabled or entries do not age out, review the configuration and operational need through change control.
- It is recommended to contact My Oracle Support for assistance, if needed.