Before Enterprise Manager 12c , job status change was sent using oraEM4JobAlert trap type. From Enterprise Manager 12c onwards, the event type corresponding to these alerts is the job_status_change alert. The value for the oraEMNGEventType in an Enterprise Manager 12c or 13c trap would be set to 'Job Status Change'.
Table C-5 Job Status Change Mappings
| Pre-12c OID Number | Pre-12c OID Name | 12c and later OID Number | 12c and later OID Name | 
|---|---|---|---|
| 
 1.3.6.1.4.1.111.15.1.2.1.2.1  | 
 oraEM4JobAlertJobName  | 
 1.3.6.1.4.1.111.15.3.1.1.29.1  | 
 oraEMNGEventSourceObjName  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.3.1  | 
 oraEM4JobAlertJobOwner  | 
 1.3.6.1.4.1.111.15.3.1.1.33.1  | 
 oraEMNGEventSourceObjOwner  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.4.1  | 
 oraEM4JobAlertJobType  | 
 1.3.6.1.4.1.111.15.3.1.1.32.1  | 
 oraEMNGEventSourceObjSubType  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.5.1  | 
 oraEM4JobAlertJobStatus  | 
 1.3.6.1.4.1.111.15.3.1.1.62.1  | 
 oraEMNGEventTypeAttr2  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.6.1  | 
 oraEM4JobAlertTargets  | 
 1.3.6.1.4.1.111.15.3.1.1.23.1  | 
 oraEMNGEventTargetType and  | 
| 
 NA  | 
 NA  | 
 1.3.6.1.4.1.111.15.3.1.1.21.1  | 
 oraEMNGEventTargetName  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.7.1  | 
 oraEM4JobAlertTimeStamp  | 
 1.3.6.1.4.1.111.15.3.1.1.10.1  | 
 oraEMNGEventReportedTime  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.8.1  | 
 oraEM4JobAlertRuleName  | 
 1.3.6.1.4.1.111.15.3.1.1.39.1  | 
 oraEMNGEventRuleSetName  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.9.1  | 
 oraEM4JobAlertRuleOwner  | 
 1.3.6.1.4.1.111.15.3.1.1.41.1  | 
 oraEMNGEventRuleOwner  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.10.1  | 
 oraEM4JobAlertMetricName  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.11.1  | 
 oraEM4JobAlertMetricValue  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.12.1  | 
 oraEM4JobAlertContext  | 
 1.3.6.1.4.1.111.15.3.1.1.44.1  | 
 oraEMNGEventContextAttrs  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.13.1  | 
 oraEM4JobAlertKeyName  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.14.1  | 
 oraEM4JobAlertKeyValue  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.15.1  | 
 oraEM4JobAlertSeverity  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.16.1  | 
 oraEM4JobAlertJobId  | 
 NA  | 
 NA  | 
| 
 1.3.6.1.4.1.111.15.1.2.1.17.1  | 
 oraEM4JobAlertJobExecId  | 
 1.3.6.1.4.1.111.15.3.1.1.61.1  | 
 oraEMNGEventTypeAttr1  | 
* Note: When mapping 1.3.6.1.4.1.111.15.1.1.1.7.1 oraEM4AlertKeyValue to a12c or 13c metric_alert event to 1.3.6.1.4.1.111.15.1.1.1.7.1 oraEM4AlertKeyValue, you must look at 1.3.6.1.4.1.111.15.3.1.1.84.1 oraEMNGEventTypeAttr24.
if oraEMNGEventTypeAttr24 is null
       then
         oraEM4AlertKeyValue is null
 
       if oraEMNGEventTypeAttr24 value =  "Number of keys=1"
         oraEM4AlertKeyValue --> oraEMNGEventTypeAttr8
 
       if oraEMNGEventTypeAttr24 value =  "Number of keys=x" where x is greater than 1
         => check the values for the following pairs of attributes. 
            <oraEMNGEventTypeAttr10, oraEMNGEventTypeAttr11>
            <oraEMNGEventTypeAttr12, oraEMNGEventTypeAttr13>
            <oraEMNGEventTypeAttr14, oraEMNGEventTypeAttr15>
            <oraEMNGEventTypeAttr16, oraEMNGEventTypeAttr17>
            <oraEMNGEventTypeAttr18, oraEMNGEventTypeAttr19>
            <oraEMNGEventTypeAttr20, oraEMNGEventTypeAttr21>
            <oraEMNGEventTypeAttr22, oraEMNGEventTypeAttr23>
            ...
            ...
As many pairs as the number of parts present in the key would be populated, the rest of it will be set to null.
For each non-null pair of attributes, the first attribute provides the name for that part of the key and second attribute provides the value for that part of the key.
Note:
OID 1.3.6.1.4.1.111.15.3.1.1.13.1 specifies the event type. Examples:
For a metric_alert event type
oraEMNGEventType=Metric Alert
For a target_availability event type,
oraEMNGEventType=Target Availability
For a job_status_change event type
oraEMNGEventType=Job Status Change