8.4 InfiniBand Connection Validation (Layer-2)

Once the cables are connected and you can see green LEDs on the ports, you must validate the InfiniBand connection.

  1. Log in to the Oracle Big Data Appliance compute node or Exalytics machine.
  2. From the Linux root shell, run the ibhosts command to verify if the newly connected (Exalytics/Oracle Big Data Appliance) machine is visible.
  3. On the Exalytics machine, run the ibstat command to see the local ports' status. If an active Subnet Manager is present, then the ports should be Active.
    [root@exalytics ~]# ibstat
    
    CA 'mlx4_0'
    CA type: MT26428
    Number of ports: 2
    Firmware version: 2.7.8130
    Hardware version: b0
    Node GUID: 0x0021280001efe984
    System image GUID: 0x0021280001efe987
    Port 1:
    State: Active
    Physical state: LinkUp
    Rate: 40
    Base lid: 209
    LMC: 0
    SM lid: 187
    Capability mask: 0x02510868
    Port GUID: 0x0021280001efe985
    Link layer: IB
    Port 2:
    State: Active
    Physical state: LinkUp
    Rate: 40
    Base lid: 73
    LMC: 0
    SM lid: 187
    Capability mask: 0x02510868
    Port GUID: 0x0021280001efe986
    Link layer: IB
     
    [root@exalytics ~]# sminfo
    
    sminfo: sm lid 187 sm guid 0x10e00c16c0c0a0, activity count 124743184 priority 14 state 3 SMINFO_MASTER
    
  4. Run the following command to make sure all the links are at 4X QDR:
    [root@exalytics ~]# ibdiagnet -ls 10 -lw 4x