70001 - Link Down

Alarm Group
vSTP
Description
Link down
Severity
Minor
Instance
<LinkName>
HA Score
Normal
Auto Clear Seconds
0 (zero)
OID
vSTPLinkDownNotify

Recovery

  1. This alarm indicates that an MTP2 link is not in In-Service state. Generally this alarm is asserted when a server or the network is undergoing maintenance or when a link has been manually disabled.
  2. If the E1/T1 trunk hosting the link or the link itself is manually disabled, then no further action is necessary.
  3. Verify that TimeSlot and LinkSpeed are configured properly.
  4. Check the event history logs at Alarms & Events > View History for additional SS7 events or alarms from this MP server.
  5. Verify that the remote E1/T1 trunk is not under maintenance.
  6. It is recommended to contact My Oracle Support for assistance if needed