5006 - Error Reading from Ethernet Device. Restart IPFE Process.

Alarm Group:
IPFE
Description:
IPFE was unable to read from an ethernet device.

Note:

If IPFE is able to read from the ethernet device, this alarm clears.
Severity:
Critical
Instance:
pcap <ethernet device name> or network interface devices added or removed
HA Score:
Degraded
Auto Clear Seconds:
N/A
OID:
ipfeIpfeEtherDeviceReadErrorNotify
Cause:
For an old IPFE version, restart IPFE to collect the data for the DSR reconfiguration like a new added Ethernet card or a deleted bond.

Recovery

  1. Navigate to Status & Manage > Server.
  2. Select the IPFE server and click Restart.

    The Are you sure you want to restart application software on the following server(s)? <server name> warning message displays.