22961 - Insufficient Memory for Feature Set
- Alarm Group:
- DIAM
- Description:
- The available memory (in kilobytes) for feature set is less than the required memory (in kilobytes). This alarm is raised when a DraWorker is brought into service and a DraWorker configured DiamaterMaxMessageSize in DpiOption table value is greater than 16KB, but the available memory on DraWorker is less than 48GB.
- Severity:
- Critical
- Instance:
- N/A
- HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- eagleXgDiameterInsufficientAvailMemNotify
- Cause:
- Alarm #22961 raises when a DraWorker is brought into service and a DraWorker configured DiamaterMaxMessageSize in DpiOption table value is greater than 16KB but the available memory on DraWorker is less than 48GB.
- Diagnostic Information:
- N/A.
Recovery:
- Make additional memory available on the DraWorker for the configured DiameterMaxMessageSize.
- If the problem persists, it is recommended to contact My Oracle Support.