22961 - Insufficient Memory for Feature Set

Alarm Group:
DIAM
Description:
The available memory (in kilobytes) for feature set is less than the required memory (in kilobytes). This alarm is raised when a DraWorker is brought into service and a DraWorker configured DiamaterMaxMessageSize in DpiOption table value is greater than 16KB, but the available memory on DraWorker is less than 48GB.
Severity:
Critical
Instance:
N/A
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
eagleXgDiameterInsufficientAvailMemNotify
Cause:
Alarm #22961 raises when a DraWorker is brought into service and a DraWorker configured DiamaterMaxMessageSize in DpiOption table value is greater than 16KB but the available memory on DraWorker is less than 48GB.
Diagnostic Information:
N/A.

Recovery:

  1. Make additional memory available on the DraWorker for the configured DiameterMaxMessageSize.
  2. If the problem persists, it is recommended to contact My Oracle Support.