22501 - DSR Application Degraded
- Alarm Group:
- APPL
- Description:
- Unable to forward requests to the DSR application because it is degraded.
- Severity:
- Major
- Instance:
- <DSR
Application Name>
Note:
The value for DSR Application Name varies depending on the DSR application generating the alarm (DCA, PCA, FABR, Policy DRA, RBAR, etc.). Use the name that corresponds to the specific DSR application in use. - HA Score:
- Normal
- Auto Clear Seconds:
- 0 (zero)
- OID:
- eagleXgDiameterDsrApplicationDegradedNotify
- Cause:
-
The alarm #22501 raises when the DSR application is in enabled state and the following DSR Application Operational Status changes occur:
- Available → Degraded
- Unavailable → Degraded
This alarm is cleared when the DSR application is in enabled state and following DSR Application Operational Status changes occur:
- Degraded → Available
- Degraded → Unavailable
- Diagnostic Information:
-
- A DSR application becomes degraded when the DSR application becomes congested if enabled. This alarm is NOT raised when the DSR application is shutting down gracefully or application is in the disabled state.
- DSR application status can be monitored from Diameter > Maintenance > Applications. Verify the admin state is set as expected.. Check the Event History logs for additional DIAM events or alarms from this MP server.
Recovery: