EvMdIwfInterwrkFail
- Measurement ID
- 15829
- Measurement Group
- MD-IWF Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The total number of interworking attempts that failed for any reason (internal or because of something from the far end).
- Collection Interval
- 5 min
- Peg Condition
- Each time an interworking attempt by MD-IWF fails.
Note:
If a translation involves a Dialog Continuation and multiple messages are exchanged to perform the translation (i.e. TC-Begin, multiple TC-Continue, TC-End), then this is counted as a single interworking attempt.Note:
A Diameter-initiated interworking attempt fails if the final Diameter Answer sent back has a non-2xxx result code. A MAP-initiated interworking attempt fails if the final MAP response message is an abort, error, or reject. It is also a failure if the configured Diameter Exception or MAP Exception is carried out. - Measurement Scope
- Site
Recovery
- It is recommended to contact unresolvable-reference.htm#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if this measurement is being pegged frequently.