RxMdIwfOrphanDiamAnswer
- Measurement ID
- 15822
- Measurement Group
- MD-IWF Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of orphan Diameter Answer messages received.
- Collection Interval
- 5 min
- Peg Condition
- Each time MD-IWF receives a Diameter Answer message for which no Pending Transaction record exists
- Measurement Scope
- Site
Recovery
- When MD-IWF sends a Diameter Request message to a DA-MP, it allocated a PTR and starts a timer (value is user configurable). The pending transaction is abandoned if a Diameter Answer response is not received within the user-configurable time limit. If this event is occurring frequently, the timer may be set too low. The Diameter Response Timeout value can be viewed via the NO GUI Screen.
- It is recommended to contact unresolvable-reference.htm#GUID-F069C6FD-5BA3-4F31-AE9E-A187D5B5F729 for assistance if needed.