Retrofitting Custom Modifications for a Table Conversion

To retrofit custom modifications for a table conversion (TC):

  1. Within OMW, use Table Conversion Design Aid to re-create all custom parts of the target UBE.

  2. Within Table Conversion Design Aid, click the Advanced ER button within the Mapping dialog.

    This option enables you to use EditER to reenter all ER statements that reference custom objects other than custom ER variables.

  3. Use the JD Edwards ER Compare tool (ER Compare button in OMW) to compare the updated local specifications (target) with the original, customized (source) specifications.

  4. Copy ER variables and then ER statements from source to target.

    Do not copy any statements that reference objects that existed only in the source (customized) environment. Those should have been created in step 2.

  5. Validate the resulting ER. Save and exit JD Edwards ER Compare.

  6. When you finish retrofitting and testing the modifications, check them back in and rebuild the package.

  7. Test and fix the modifications, and then rebuild and redeploy the corrected package. Repeat this step until all the modifications are functioning properly.