Setting Up Conversion Tables

Access the Conversion Table Interface Revisions form.

Table

Specify the density conversion algorithm to be used in calculations.

Minimum and Maximum

Enter a value that specifies the minimum density that is allowed for a product.

You can allow the value to be provided by default from the table that you are working with.

The table values and their corresponding ranges are:

5B: 0 - 85 API Gravity

23B: .6535 – 1.0760 Relative Density

53B: 653 - 1075 Density in kg/M3

53D: 800 - 1164 Density in kg/M3

BIT: 700 - 1200 Density in kg/M3

Note: For most tables, multiple ranges exist that depend on temperature. The ranges listed are the lowest and highest numbers for all ranges within each specified table.
Type

Enter a code used to identify the type of density that the Density Table expects as input. If this density type is different than the Density Table, results will be unpredictable. Values are:

A: Absolute Density

G: API Specific Gravity

R: Relative Density

Business Function

Enter a value that specifies whether a JD Edwards EnterpriseOne business function or an outside executable is used for conversions related to the specified table. Values are:

Y or 1: A business function is used.

N or 0: A third-party executable is used.