Get one configuration
get
/fscmRestApi/resources/11.13.18.05/configurations/{ConfigurationId}
Request
Path Parameters
-
ConfigurationId(required): string
Value that uniquely identifies a configuration according to the ConfigHeaderId and ConfigRevisionId attributes. This value is derived by concatenating the value of ConfigHeaderId and ConfigRevisionId, and seperating them by an underscore. For example: 300100557352135_300100557352136 where ConfigHeaderId is 300100557352135 and ConfigRevisionId is 300100557352136
Query Parameters
-
dependency: string
This parameter specifies dependencies which are fields that are set before and rolled back after generating the response. Generally they are used to preview the effects of an attribute change. The fields specified in this parameter are always set in the resource instance in question. When a child resource collection is requested and the parameter is set, the fields will be set in the parent resource instance before generating the resource collection payload. The value of this query parameter is a set of dependency fields. Example: dependency=ProductId=2
Format: <attr1>=<val1>,<attr2>=<value2> -
expand: string
When this parameter is provided, the specified children are included in the resource payload (instead of just a link). The value of this query parameter is "all" or "". More than one child can be specified using comma as a separator. Example: ?expand=Employees,Localizations. Nested children can also be provided following the format "Child.NestedChild" (Example: ?expand=Employees.Managers). If a nested child is provided (Example: Employees.Managers), the missing children will be processed implicitly. For example, "?expand=Employees.Managers" is the same as "?expand=Employees,Employees.Managers" (which will expand Employees and Managers).
-
fields: string
This parameter filters the resource fields. Only the specified fields are returned, which means that if no fields are specified, no fields are returned (useful to get only the links). If an indirect child resource is provided (Example: Employees.Managers), the missing children will be processed implicitly. For example, "?fields=Employees.Managers:Empname" is the same as "?fields=;Employees:;Employees.Managers:Empname" (which will only return the "Empname" field for Managers). the value of this query parameter is a list of resource fields. The attribute can be a direct (Example: Employees) or indirect (Example: Employees.Managers) child. It cannot be combined with expand query parameter. If both are provided, only fields will be considered.
Format: ?fields=Attribute1,Attribute2
Format for fields in child resource: ?fields=Accessor1:Attribute1,Attribute2 -
links: string
This parameter can be used to show only certain links while accessing a singular resource or a resource collection. The parameter value format is a comma-separated list of : <link_relation>
Example:
self,canonical -
onlyData: boolean
The resource item payload will be filtered in order to contain only data (no links section, for example).
Header Parameters
-
Metadata-Context:
If the REST API supports runtime customizations, the shape of the service may change during runtime. The REST client may isolate itself from these changes or choose to interact with the latest version of the API by specifying this header. For example: Metadata-Context:sandbox="TrackEmployeeFeature".
-
REST-Framework-Version:
The protocol version between a REST client and service. If the client does not specify this header in the request the server will pick a default version for the API.
There's no request body for this operation.
Back to TopResponse
Supported Media Types
- application/json
Default Response
The following table describes the default response for this task.
Headers
-
Metadata-Context(required):
If the REST API supports runtime customizations, the shape of the service may change during runtime. The REST client may isolate itself from these changes or choose to interact with the latest version of the API by specifying this header. For example: Metadata-Context:sandbox="TrackEmployeeFeature".
-
REST-Framework-Version(required):
The protocol version between a REST client and service. If the client does not specify this header in the request the server will pick a default version for the API.
Root Schema : configurations-item-response
Type:
Show Source
object
-
AdditionalRootLineAttributes: string
Value that indicates additional line attributes for the configurable item. This attribute includes details that the application can send to a downstream system.
-
CallingApplicationCode: string
Maximum Length:
1000
Abbreviation that identifies the name of the application that called this resource. The resource uses this name to identify the user interface to call when starting an interactive session. -
CallingApplicationId: integer
(int64)
Value that uniquely identifies the application that called this resource. This value is internal and is used by applications in Oracle Fusion trading community or Oracle Fusion applications.
-
ConfigHeaderId: integer
(int64)
Value that uniquely identifies the configuration header.
-
ConfigRevisionId: integer
(int64)
Value that uniquely identifies the configuration revision.
-
ConfigurationId: string
Maximum Length:
255
Value that uniquely identifies a configuration according to the ConfigHeaderId and ConfigRevisionId attributes. This value is derived by concatenating the value of ConfigHeaderId and ConfigRevisionId, and seperating them by an underscore. For example: 300100557352135_300100557352136 where ConfigHeaderId is 300100557352135 and ConfigRevisionId is 300100557352136 -
ConfigurationLineAttributes: array
Configuration Line Attributes
Title:
Configuration Line Attributes
The Configuration Line Attributes resource manages transactional item attributes for one configuration or for one configuration line. -
ConfigurationLines: array
Configuration Lines
Title:
Configuration Lines
The Configuration Lines resource manages configuration lines of a configuration. -
ConfigurationMessages: array
Configuration Messages
Title:
Configuration Messages
The Configuration Messages resource manages messages for configurations. -
ConfigurationSessionToken: string
Value that identifies an active configuration session. If the FinishConfigurationFlag attribute is False, then the application creates this token when it creates the configuration resource. You must add this token to the HTTP request header for each subsequent request to maintain continuity of the requests for the interactive configuration. HTTP header attribute name will be the same.
-
ConfigurationState: string
Contains one of the following values: Active for an active configuration; Finished for a saved configuration. The default value is Active.
-
connectedItems: array
Connected Items
Title:
Connected Items
The Connected Items resource manages the connected items associated with a configuration. -
CreatedBy: string
Read Only:
true
Maximum Length:64
User who created the configuration. -
CreatedOn: string
(date-time)
Read Only:
true
Date and time when the configuration was created. -
CustomParameters: string
Extensible parameter to use during the configuration session. Each extensible parameter includes a name and value. It includes details that you can specify during configuration to extend the inventory item that you are configuring.
-
Description: string
Maximum Length:
1000
Description of the configuration. -
FinishConfigurationFlag: boolean
Maximum Length:
255
Contains one of the following values: true or false. If true, then finish the configuration immediately when creating a configuration resource. If false, then do not finish the configuration immediately. The default value is false. -
HeaderAttributes: string
Value that indicates header attributes for a quote, an order, or a cart. This attribute includes identifying details, such as the customer name and ship-to location.
-
InventoryItemNumber: string
Maximum Length:
300
Inventory item number the application uses to start the configuration. -
InventoryOrganizationCode: string
Maximum Length:
18
Abbreviation that identifies validation organization of the item or service that the configuration contains. -
LastUpdatedBy: string
Read Only:
true
Maximum Length:64
User who most recently updated the configuration, including the interaction with the configuration model nodes. -
LastUpdatedOn: string
(date-time)
Read Only:
true
Date and time when the configuration was updated. -
LineQuantity: integer
Default Value:
1
Line quantity for the configuration. The default value is 1. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
ManualPriceAdjustments: string
Price adjustments to apply during configuration.
-
modelNodes: array
Model Nodes
Title:
Model Nodes
The Model Nodes resource manages model nodes for an active configuration. -
Name: string
Maximum Length:
255
Name of the configuration. -
OutputMode: string
Maximum Length:
255
Contains one of the following values. Full: output includes the entire configuration hierarchy, including option classes. Filtered: output does not include option classes. The default value is Filtered. -
SessionEffectiveDate: string
(date-time)
Date and time to use when loading the model definition for the configuration session. This date determines the configuration options that are available, depending on how the Product Configurator Manager modeled the item. Valid formats include yyyy-MM-dd; for example: 2019-04-14, and yyyy-MM-ddTHH:mm:ssZ; for example: 2019-04-14T10:37:40-0500 where -0500 indicates offset from GMT.
-
ValidConfigurationFlag: boolean
Maximum Length:
1
Contains one of the following values: true or false. If true, then the configuration is valid. If false, then the configuration is not valid. The default value is true. This attribute is read-only.
Nested Schema : Configuration Line Attributes
Type:
array
Title:
Configuration Line Attributes
The Configuration Line Attributes resource manages transactional item attributes for one configuration or for one configuration line.
Show Source
Nested Schema : Configuration Lines
Type:
array
Title:
Configuration Lines
The Configuration Lines resource manages configuration lines of a configuration.
Show Source
Nested Schema : Configuration Messages
Type:
array
Title:
Configuration Messages
The Configuration Messages resource manages messages for configurations.
Show Source
Nested Schema : Connected Items
Type:
array
Title:
Connected Items
The Connected Items resource manages the connected items associated with a configuration.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Model Nodes
Type:
array
Title:
Model Nodes
The Model Nodes resource manages model nodes for an active configuration.
Show Source
-
Array of:
object Discriminator: NodeType
Discriminator:
{ "propertyName":"NodeType", "mapping":{ "BOOLEAN_FEATURE":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_BooleanFeatureVO-item-response", "COMPONENT_PORT":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_ComponentPortVO-item-response", "DECIMAL_FEATURE":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_DecimalFeatureVO-item-response", "INTEGER_FEATURE":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_IntegerFeatureVO-item-response", "MODEL_ITEM":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_ModelItemVO-item-response", "OPTION":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_OptionVO-item-response", "OPTION_CLASS_ITEM":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_OptionClassItemVO-item-response", "OPTION_FEATURE":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_OptionFeatureVO-item-response", "ROOT_MODEL_ITEM":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_RootNodeVO-item-response", "STANDARD_ITEM":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_StandardItemVO-item-response", "TEXT_FEATURE":"#/components/schemas/oracle_apps_scm_configurator_runtime_restmodel_view_TextFeatureVO-item-response" } }
Nested Schema : configurations-ConfigurationLineAttributes-item-response
Type:
Show Source
object
-
AttributeId: integer
(int64)
Read Only:
true
Value that uniquely identifies the transactional attribute of the inventory item. -
ConfigHeaderId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration header. -
ConfigLineAttributeId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration line attribute. -
ConfigLineId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration line of the transactional item attribute. -
ConfigRevisionId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration revision. -
InternalName: string
Read Only:
true
Maximum Length:100
Name of the transactional item attribute. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
NumberValue: number
Read Only:
true
Value of the line attribute for a transactional item attribute that is a number. -
UomCode: string
Read Only:
true
Maximum Length:3
Abbreviation that identifies the unit of measure for a transactional item attribute that is a number. -
ValueId: integer
(int64)
Read Only:
true
Value that identifies the transactional item attribute value. -
VarcharValue: string
Read Only:
true
Maximum Length:4000
Value of the line attribute for a transactional item attribute that is a string.
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : link
Type:
Show Source
object
-
href: string
Title:
hyperlink reference
The URI to the related resource. -
kind: string
Title:
kind
Allowed Values:[ "collection", "item", "describe", "other" ]
The kind of the related resource. -
name: string
Title:
name
The name of the link to the related resource. -
properties: object
properties
-
rel: string
Title:
relation
Allowed Values:[ "self", "lov", "parent", "canonical", "child", "enclosure", "action", "custom" ]
The name of the relation to the resource instance. Example: self.
Nested Schema : properties
Type:
Show Source
object
-
changeIndicator: string
Change indicator or the ETag value of the resource instance.
Nested Schema : configurations-ConfigurationLines-item-response
Type:
Show Source
object
-
ConfigHeaderId: integer
(int64)
Value that uniquely identifies the configuration header.
-
ConfigLineId: integer
(int64)
Value that uniquely identifies the configuration line.
-
ConfigRevisionId: integer
(int64)
Value that uniquely identifies the configuration revision.
-
ConfiguratorPath: string
Maximum Length:
2000
Configuration hierarchy path of the inventory item. The configurator uses this attribute to identify the item hierarchy position in the configuration. -
InventoryItemId: integer
(int64)
Value that uniquely identifies the inventory item number of the configuration item.
-
InventoryItemNumber: string
Read Only:
true
Maximum Length:300
Inventory item number of the configuration item. -
InventoryItemType: number
Title:
Structure Item Type
Read Only:true
Type of inventory item. It contains one of the following values: 1 for model, 2 for option class, and 4 for standard item. -
InventoryOrganizationCode: string
Read Only:
true
Maximum Length:18
Abbreviation that identifies the inventory item organization. -
InventoryOrganizationId: integer
(int64)
Value that uniquely identifies the organization that the inventory item references.
-
LineQuantity: number
Total ordered line quantity of the inventory item.
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
ParentConfigLineId: integer
Value that uniquely identifies the parent line of the configuration line.
-
UnitQuantity: number
Ordered quantity of the inventory item.
-
UomCode: string
Maximum Length:
3
Abbreviation that identifies the unit of measure for the total ordered quantity.
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : configurations-ConfigurationMessages-item-response
Type:
Show Source
object
-
ConfigHeaderId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration header. -
ConfigLineId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration line for this message. -
ConfigRevisionId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration revision. -
DetailedMessageType: string
Read Only:
true
Maximum Length:200
Detail message type for an error that occurs during validation, such as a conflict or a required input that is missing. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
MessageId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration message. -
MessageText: string
Read Only:
true
Maximum Length:2000
Text of the error message, if any. -
MessageType: string
Read Only:
true
Maximum Length:1
Type of message. It contains one of the following values: I for information, W for warning, and E for error.
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : configurations-connectedItems-item-response
Type:
Show Source
object
-
ConfigHeaderId: integer
Read Only:
true
Value that uniquely identifies the configuration header. -
ConfigRevisionId: integer
(int64)
Read Only:
true
Value that uniquely identifies the configuration revision. -
ConnectedItemId: integer
(int64)
Read Only:
true
Value that uniquely identifies the connected item associated with the configuration. -
InventoryItemId: integer
(int64)
Read Only:
true
Value that uniquely identifies the inventory item of the connected item. -
InventoryItemNumber: string
Read Only:
true
Maximum Length:300
Inventory item number of the connected item. -
InventoryItemType: number
Read Only:
true
Type of connected inventory item. Valid value is 4 for a standard item. -
InventoryOrganizationCode: string
Read Only:
true
Maximum Length:18
Abbreviation that identifies the connected inventory item organization. -
InventoryOrganizationId: integer
(int64)
Read Only:
true
Value that uniquely identifies the organization that the connected inventory item references. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
ParentConfigLineId: integer
(int64)
Read Only:
true
Value that uniquely identifies the parent line of the connected item. -
Quantity: number
Read Only:
true
Total ordered line quantity of the connected item. -
UomCode: string
Read Only:
true
Maximum Length:3
Abbreviation that identifies the unit of measure for the total ordered quantity of the connected item.
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Discriminator: NodeType
Type:
object
Discriminator: NodeType
Discriminator Values
- BOOLEAN_FEATURE
- COMPONENT_PORT
- DECIMAL_FEATURE
- INTEGER_FEATURE
- MODEL_ITEM
- OPTION
- OPTION_CLASS_ITEM
- OPTION_FEATURE
- ROOT_MODEL_ITEM
- STANDARD_ITEM
- TEXT_FEATURE
Match One Schema
Show Source
-
BOOLEAN_FEATURE -
object
oracle_apps_scm_configurator_runtime_restmodel_view_BooleanFeatureVO-item-response
-
COMPONENT_PORT -
object
oracle_apps_scm_configurator_runtime_restmodel_view_ComponentPortVO-item-response
-
DECIMAL_FEATURE -
object
oracle_apps_scm_configurator_runtime_restmodel_view_DecimalFeatureVO-item-response
-
INTEGER_FEATURE -
object
oracle_apps_scm_configurator_runtime_restmodel_view_IntegerFeatureVO-item-response
-
MODEL_ITEM -
object
oracle_apps_scm_configurator_runtime_restmodel_view_ModelItemVO-item-response
-
OPTION -
object
oracle_apps_scm_configurator_runtime_restmodel_view_OptionVO-item-response
-
OPTION_CLASS_ITEM -
object
oracle_apps_scm_configurator_runtime_restmodel_view_OptionClassItemVO-item-response
-
OPTION_FEATURE -
object
oracle_apps_scm_configurator_runtime_restmodel_view_OptionFeatureVO-item-response
-
ROOT_MODEL_ITEM -
object
oracle_apps_scm_configurator_runtime_restmodel_view_RootNodeVO-item-response
-
STANDARD_ITEM -
object
oracle_apps_scm_configurator_runtime_restmodel_view_StandardItemVO-item-response
-
TEXT_FEATURE -
object
oracle_apps_scm_configurator_runtime_restmodel_view_TextFeatureVO-item-response
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_BooleanFeatureVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:BOOLEAN_FEATURE
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
SelectedFlag: boolean
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_ComponentPortVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxInstances: integer
Read Only:
true
-
DefinitionMaxQuantity: number
Read Only:
true
-
DefinitionMinInstances: integer
Read Only:
true
-
DefinitionMinQuantity: number
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
InstanceCount: integer
Read Only:
true
-
InstantiationType: string
Read Only:
true
-
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
IsBoundQuantitySumFlag: boolean
Read Only:
true
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
MaxInstances: integer
Read Only:
true
-
MaxQuantitySum: number
Read Only:
true
-
MinInstances: integer
Read Only:
true
-
MinQuantitySum: number
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:COMPONENT_PORT
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
QuantitySum: number
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_DecimalFeatureVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxValue: number
Read Only:
true
-
DefinitionMinValue: number
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
MaxValue: number
Read Only:
true
-
MinValue: number
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:DECIMAL_FEATURE
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true. -
Value: number
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_IntegerFeatureVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxValue: integer
Read Only:
true
-
DefinitionMinValue: integer
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
MaxValue: integer
Read Only:
true
-
MinValue: integer
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:INTEGER_FEATURE
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true. -
Value: integer
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_ModelItemVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxQuantity: number
Read Only:
true
-
DefinitionMinQuantity: number
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
InstanceName: string
Read Only:
true
Maximum Length:255
-
InstanceNumber: integer
Read Only:
true
-
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
IsBoundQuantityFlag: boolean
Read Only:
true
-
IsConfiguredFlag: boolean
Read Only:
true
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
MaxQuantity: number
Read Only:
true
-
MinQuantity: number
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:MODEL_ITEM
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
Quantity: number
-
SelectedFlag: boolean
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_OptionVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxQuantity: number
Read Only:
true
-
DefinitionMinQuantity: number
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
IsBoundQuantityFlag: boolean
Read Only:
true
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
MaxQuantity: number
Read Only:
true
-
MinQuantity: number
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:OPTION
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
Quantity: number
-
SelectedFlag: boolean
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_OptionClassItemVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxQuantity: number
Read Only:
true
-
DefinitionMaxSelected: integer
Read Only:
true
-
DefinitionMinQuantity: number
Read Only:
true
-
DefinitionMinSelected: integer
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
IsBoundQuantityFlag: boolean
Read Only:
true
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
MaxQuantity: number
Read Only:
true
-
MaxSelected: integer
Read Only:
true
-
MinQuantity: number
Read Only:
true
-
MinSelected: integer
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:OPTION_CLASS_ITEM
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
Quantity: number
Read Only:
true
-
SelectedCount: integer
Read Only:
true
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_OptionFeatureVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxSelected: integer
Read Only:
true
-
DefinitionMinSelected: integer
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
MaxSelected: integer
Read Only:
true
-
MinSelected: integer
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:OPTION_FEATURE
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
SelectedCount: integer
Read Only:
true
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_RootNodeVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
Description: string
Read Only:
true
Description of the model node. -
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:ROOT_MODEL_ITEM
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
Quantity: integer
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_StandardItemVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxQuantity: number
Read Only:
true
-
DefinitionMinQuantity: number
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DetailedSelectionState: string
Read Only:
true
-
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
IsBoundQuantityFlag: boolean
Read Only:
true
-
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
LogicState: string
Read Only:
true
-
MaxQuantity: number
Read Only:
true
-
MinQuantity: number
Read Only:
true
-
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:STANDARD_ITEM
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
Quantity: number
-
SelectedFlag: boolean
-
SelectionState: string
Read Only:
true
-
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true.
Nested Schema : oracle_apps_scm_configurator_runtime_restmodel_view_TextFeatureVO-item-response
Type:
Show Source
object
-
ChangedByAutocompleteFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the selection state or quantity of the model node was changed as a result of the most recent Auto-Complete process. If false, then the selection state or quantity of the model node was not changed as a result of the most recent Auto-Complete process. The default value is false. -
DefinitionMaxLength: integer
Read Only:
true
-
Description: string
Read Only:
true
Description of the model node. -
DisplayName: string
Read Only:
true
Display name of the model node. -
DisplayNamePath: string
Read Only:
true
Fully qualified display name path of the model node. -
HasChildrenFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has a direct descendant. If false, then the model node is a leaf node. This attribute does not have a default value. -
HasTransactionalAttributesFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node has transactional attributes. If false, then the model node has no transactional item attributes. This attribute does not have a default value. -
InErrorModeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then input is required for the model node. If false, then input is not required for the model node. The default value is false. This attribute is updated on each request for Finish or Auto-Complete. -
InputRequiredFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is marked User Input Required in Configurator Modeling Environment (or by other means such as a Configurator Extension), regardless of whether or not it is bound. (Related to display of Input Required indicator.) If false, then the model node is not required. This attribute does not have a default value. -
InputRequiredInSubtreeFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node or a descendant is required prior to finishing the configuration. If false, then the model node or a descendant are not required prior to finishing the configuration. This attribute does not have a default value. -
IsBoundFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is completely bound at run time. This means both domain and cardinality, if applicable. If false, the mode node is not bound at run time. This attribute does not have a default value. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
Name: string
Read Only:
true
Name of the model node. -
NodeId: integer
Read Only:
true
Value that uniquely identifies a model node in an active configuration. -
NodeType: string
Read Only:
true
Default Value:TEXT_FEATURE
Type of the model node. Valid values are MODEL_ITEM, OPTION_CLASS_ITEM, COMPONENT_PORT, STANDARD_ITEM, OPTION_FEATURE, OPTION, BOOLEAN_FEATURE, INTEGER_FEATURE, DECIMAL_FEATURE, and TEXT_FEATURE. -
OverrideConflictFlag: boolean
Contains one of the following values: true, false, or null. When true and if the conflict is overridable, then the new change with the POST/PATCH request will be retained and the previous selections or quantity update will be undone. If false, then the previous selections or quantity change will be retained. If the conflict is non-overridable, then passing in true or false has no effect, the previous selection or quantity change is retained. If the value is null or the attribute is not passed in the request payload, then the conflict message is displayed in the response payload. If the conflict is overridable, repeat the request with a true or false value to achieve the desired behavior. The default value is null.
-
ParentNodeId: integer
Read Only:
true
Value that uniquely identifies the parent node of the model node. -
ProposedFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is proposed for selection. If false, then the model node is not proposed for selection. This attribute does not have a default value. It reflects the current state or value of the model node as a result of a Default or a Search Decision rule. -
ValidFlag: boolean
Read Only:
true
Contains one of the following values: true or false. If true, then the model node is valid in the current configuration state. If false, then the model node is invalid in the current configuration state. The default value is true. -
Value: string
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Nested Schema : Links
Type:
array
Title:
Links
The link relations associated with the resource instance.
Show Source
Links
- ConfigurationLineAttributes
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
The Configuration Line Attributes resource manages transactional item attributes for one configuration or for one configuration line. - ConfigurationId:
- ConfigurationLines
-
Operation: /fscmRestApi/resources/11.13.18.05/configurations/{ConfigurationId}/child/ConfigurationLinesParameters:
- ConfigurationId:
$request.path.ConfigurationId
The Configuration Lines resource manages configuration lines of a configuration. - ConfigurationId:
- ConfigurationMessages
-
Operation: /fscmRestApi/resources/11.13.18.05/configurations/{ConfigurationId}/child/ConfigurationMessagesParameters:
- ConfigurationId:
$request.path.ConfigurationId
The Configuration Messages resource manages messages for configurations. - ConfigurationId:
- connectedItems
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
The Connected Items resource manages the connected items associated with a configuration. - ConfigurationId:
- copy
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
Copies a configuration. - ConfigurationId:
- finish
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
Finishes a configuration. - ConfigurationId:
- modelNodes
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
The Model Nodes resource manages model nodes for an active configuration. - ConfigurationId:
- reviseQuantity
-
Operation: /fscmRestApi/resources/11.13.18.05/configurations/{ConfigurationId}/action/reviseQuantityParameters:
- ConfigurationId:
$request.path.ConfigurationId
Revises the quantity of a configuration. - ConfigurationId:
- validate
-
Parameters:
- ConfigurationId:
$request.path.ConfigurationId
Validates a configuration. - ConfigurationId:
Examples
This example describes how to get one configuration.
Example cURL Command
Use the following cURL command to submit a request on the REST resource:
curl -u username:password "https://servername/fscmRestApi/resources/version/configurations/ConfigurationId"
Example Response Body
The following shows an example of the response body in JSON format.
{ "ConfigHeaderId" : 300100071812037, "ConfigRevisionId" : 300100071812038, "OutputMode" : "filtered", "Name" : "zcz_ordsch_ss_M1 (Tue Jun 26 00:00:01 UTC 2040)", "Description" : "zcz_ordsch_ss_M1", "ValidConfigurationFlag" : true, "SessionEffectiveDate" : "2040-06-26T00:00:01-06:00", "CallingApplicationId" : 2000, ... }