Create a meter reading
/fscmRestApi/resources/11.13.18.05/meterReadings
Request
-
Metadata-Context:
If the REST API supports runtime customizations, the shape of the service may change during runtime. The REST client may isolate itself from these changes or choose to interact with the latest version of the API by specifying this header. For example: Metadata-Context:sandbox="TrackEmployeeFeature".
-
REST-Framework-Version:
The protocol version between a REST client and service. If the client does not specify this header in the request the server will pick a default version for the API.
- application/json
object
-
AssetId: integer
Unique identifier of an asset. Either the asset number or asset identifier is required for a new reading. When the asset identifier is provided with the meter identifier, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter code and asset number may be used to identify an individual asset meter and record a new meter reading.
-
AssetNumber: string
Unique number of an asset. Either the asset number or asset identifier is required for a new reading. When the asset number is provided with the meter code, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter identifier and asset identifier may be used to identify an individual asset meter and record a new meter reading.
-
Comments: string
Maximum Length:
240
Comments about a meter reading. If defined, they will be displayed during retrieval of historical readings. -
DisabledFlag: boolean
Maximum Length:
1
Default Value:false
Contains one of the following values: true or false. If true, then the meter reading has been disabled. If false, then the meter reading hasn't been disabled. This attribute doesn't have a default value. This attribute can be passed during update to disable an active reading in history, resulting in the cancelation and recreation of all active readings later in history. -
MeterCode: string
Unique identifying code of a meter template definition. Either the meter code or meter ID is required for a new reading. When the meter code is provided with the asset number, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter identifier and asset identifier may be used to identify an individual asset meter and record a new meter reading.
-
MeterId: integer
(int64)
Value that uniquely identifies the asset meter. The meter identifier along with the asset identifier is used to identify an individual asset meter and record a new meter reading. Alternatively, the meter code and asset number may be used to identify an individual asset meter and record a new meter reading.
-
MeterReadingId: integer
(int64)
Value that uniquely identifies a meter reading. This attribute is read-only. The value of this attribute is created when a meter reading is created for an asset meter.
-
MeterUsageCode: string
Abbreviation that uniquely identifies whether the meter reading is created for an asset or for a contract line. Valid values are ORA_ASSET or ORA_CONTRACT_LINE. A list of accepted values is defined in the lookup type ORA_CSE_METER_USAGE_CODE.
-
NetValue: number
Value that represents the cumulative reading value for an asset meter, irrespective of Reset or Rollover events, over time. It is incremented by the recording new meter readings. This attribute is read-only.
-
ReadingDate: string
(date-time)
Title:
Reading Date-Time
Date and time when the meter reading was taken. It must be less than or equal to the system date and time, greater than the last reading date and time, and is validated against the asset meter active start and end dates. -
ReadingTypeCode: string
Maximum Length:
30
Code that identifies the reading type of a meter reading. Valid values include ORA_ABSOLUTE, ORA_CHANGE, or ORA_RESET. A list of accepted values is defined in the lookup type ORA_CSE_READING_TYPE_CODE. -
ReadingValue: number
Value of a meter reading. For continuous absolute meters, the reading value must be less than, equal to, or greater than the last reading in history. For continuous change meters, the reading value must be greater than or equal to zero. If the meter template has a reading minimum, maximum, or rollover maximum defined, then the reading value must also pass these validations during creation.
-
ResetFlag: boolean
Maximum Length:
1
Contains one of the following values: true or false. If true, then the meter reading resulted in a reset of the meter. If false, then the meter reading did not result in a reset of the meter. The default value is false. This attribute is read-only. When creating the reading, if the reading type code is ORA_RESET, then this attribute will be automatically set to true. -
RolloverFlag: boolean
Maximum Length:
1
Contains one of the following values: true or false. If true, then the meter reading resulted in a rollover of the meter. If false, then the meter reading didn't result in a rollover of the meter. The default value is false. For continuous absolute ascending meters, passing a value of true will relax the validations that the reading value must be less than, equal to, or greater than the last reading in history.
Response
- application/json
Default Response
-
Metadata-Context(required):
If the REST API supports runtime customizations, the shape of the service may change during runtime. The REST client may isolate itself from these changes or choose to interact with the latest version of the API by specifying this header. For example: Metadata-Context:sandbox="TrackEmployeeFeature".
-
REST-Framework-Version(required):
The protocol version between a REST client and service. If the client does not specify this header in the request the server will pick a default version for the API.
object
-
AssetId: integer
Unique identifier of an asset. Either the asset number or asset identifier is required for a new reading. When the asset identifier is provided with the meter identifier, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter code and asset number may be used to identify an individual asset meter and record a new meter reading.
-
AssetNumber: string
Unique number of an asset. Either the asset number or asset identifier is required for a new reading. When the asset number is provided with the meter code, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter identifier and asset identifier may be used to identify an individual asset meter and record a new meter reading.
-
Comments: string
Maximum Length:
240
Comments about a meter reading. If defined, they will be displayed during retrieval of historical readings. -
DisabledFlag: boolean
Maximum Length:
1
Default Value:false
Contains one of the following values: true or false. If true, then the meter reading has been disabled. If false, then the meter reading hasn't been disabled. This attribute doesn't have a default value. This attribute can be passed during update to disable an active reading in history, resulting in the cancelation and recreation of all active readings later in history. -
InitialFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the meter reading was created and an initial reading occurred. If false, then an initial reading didn't occur. This attribute doesn't have a default value. This attribute is read-only. -
links: array
Links
Title:
Links
The link relations associated with the resource instance. -
MeterCode: string
Unique identifying code of a meter template definition. Either the meter code or meter ID is required for a new reading. When the meter code is provided with the asset number, it's used to identify an individual asset meter and record a new meter reading. Alternatively, the meter identifier and asset identifier may be used to identify an individual asset meter and record a new meter reading.
-
MeterDefinitionId: integer
(int64)
Title:
Meter Definition ID
Read Only:true
Value that uniquely identifies a meter template. The value is saved during reading creation as additional reference to the meter code or id that is passed. This attribute is read-only. -
MeterId: integer
(int64)
Value that uniquely identifies the asset meter. The meter identifier along with the asset identifier is used to identify an individual asset meter and record a new meter reading. Alternatively, the meter code and asset number may be used to identify an individual asset meter and record a new meter reading.
-
MeterReadingId: integer
(int64)
Value that uniquely identifies a meter reading. This attribute is read-only. The value of this attribute is created when a meter reading is created for an asset meter.
-
MeterUsageCode: string
Abbreviation that uniquely identifies whether the meter reading is created for an asset or for a contract line. Valid values are ORA_ASSET or ORA_CONTRACT_LINE. A list of accepted values is defined in the lookup type ORA_CSE_METER_USAGE_CODE.
-
ModifiedFlag: boolean
Read Only:
true
Maximum Length:1
Contains one of the following values: true or false. If true, then the meter reading has been modified. If false, then the meter reading hasn't been modified. This attribute doesn't have a default value. This attribute is read-only. -
NetValue: number
Value that represents the cumulative reading value for an asset meter, irrespective of Reset or Rollover events, over time. It is incremented by the recording new meter readings. This attribute is read-only.
-
OssSubscriptionProductId: integer
(int64)
Read Only:
true
Unique identifier of the subscription product. -
ProductName: string
Title:
Product Name
Read Only:true
Maximum Length:300
Name of the subscription product. -
ProductNumber: string
Title:
Product Number
Read Only:true
Maximum Length:300
Subscription product number. -
ReadingDate: string
(date-time)
Title:
Reading Date-Time
Date and time when the meter reading was taken. It must be less than or equal to the system date and time, greater than the last reading date and time, and is validated against the asset meter active start and end dates. -
ReadingTypeCode: string
Maximum Length:
30
Code that identifies the reading type of a meter reading. Valid values include ORA_ABSOLUTE, ORA_CHANGE, or ORA_RESET. A list of accepted values is defined in the lookup type ORA_CSE_READING_TYPE_CODE. -
ReadingValue: number
Value of a meter reading. For continuous absolute meters, the reading value must be less than, equal to, or greater than the last reading in history. For continuous change meters, the reading value must be greater than or equal to zero. If the meter template has a reading minimum, maximum, or rollover maximum defined, then the reading value must also pass these validations during creation.
-
ResetFlag: boolean
Maximum Length:
1
Contains one of the following values: true or false. If true, then the meter reading resulted in a reset of the meter. If false, then the meter reading did not result in a reset of the meter. The default value is false. This attribute is read-only. When creating the reading, if the reading type code is ORA_RESET, then this attribute will be automatically set to true. -
RolloverFlag: boolean
Maximum Length:
1
Contains one of the following values: true or false. If true, then the meter reading resulted in a rollover of the meter. If false, then the meter reading didn't result in a rollover of the meter. The default value is false. For continuous absolute ascending meters, passing a value of true will relax the validations that the reading value must be less than, equal to, or greater than the last reading in history. -
SubscriptionProductPuid: string
Title:
Subscription Product Number
Read Only:true
Maximum Length:120
Value that uniquely identifies the subscription product.
array
Links
object
-
href: string
Title:
hyperlink reference
The URI to the related resource. -
kind: string
Title:
kind
Allowed Values:[ "collection", "item", "describe", "other" ]
The kind of the related resource. -
name: string
Title:
name
The name of the link to the related resource. -
properties: object
properties
-
rel: string
Title:
relation
Allowed Values:[ "self", "lov", "parent", "canonical", "child", "enclosure", "action", "custom" ]
The name of the relation to the resource instance. Example: self.
object
-
changeIndicator: string
Change indicator or the ETag value of the resource instance.
Examples
This example describes how to create one meter reading.
Example cURL Command
Use this cURL command to submit a request on the REST resource.
curl -u username:password -X POST -H "Content-Type:application/vnd.oracle.adf.resourceitem+json" -d 'request payload' servername/fscmRestApi/resources/version/meterReadings"
Example 1 Request Body
The following example includes the contents of the request body for an asset meter in JSON format. You replace the request payload in the cURL command with the contents of the Example Request Body. The request payload specifies attribute values that the command will use in the record that it creates.
{ "AssetNumber": "F0554-02", "MeterCode": "0554 HOURS", "ReadingDate": "2018-03-14T16:27:00-07:00", "ReadingTypeCode": "ORA_ABSOLUTE", "MeterUsageCode": "ORA_ASSET", "ReadingValue": 1108.12, "Comments": "24ndsept Reading-108.12" }
Example 1 Response Body
This example includes the contents of the response body in JSON format:
{ "MeterReadingId": 300100141425958, "ReadingValue": 1108.12, "ReadingDate": "2018-03-14T23:27:00+00:00", "ReadingTypeCode": "ORA_ABSOLUTE", "NetValue": 1108.12, "Comments": "24ndsept Reading-108.12", "RolloverFlag": false, "ResetFlag": false, "ModifiedFlag": null, "InitialFlag": null, "DisabledFlag": null, "MeterDefinitionId": null, "MeterCode": null, "MeterId": 300100141395129, "MeterUsageCode": "ORA_ASSET", "AssetNumber": null, "AssetId": null }
Example 2 Request Body
This example includes the contents of the request body for an asset meter in JSON format to create one meter reading according to the asset identifier and meter identifier. You replace the request payload in the cURL command with the contents of the Example Request Body. The request payload specifies attribute values that the command will use in the record that it creates.
{ "AssetId": 300100117993592, "MeterId": "300100141395129", "ReadingDate": "2018-03-14T16:30:00-07:00", "ReadingTypeCode": "ORA_ABSOLUTE", "MeterUsageCode": "ORA_ASSET", "ReadingValue": 1208.12, "Comments": "24ndsept Reading-108.12" }
Example 2 Response Body
This example includes the contents of the response body in JSON format:
{ "MeterReadingId": 300100141428011, "ReadingValue": 1208.12, "ReadingDate": "2018-03-14T23:30:00+00:00", "ReadingTypeCode": "ORA_ABSOLUTE", "NetValue": 1208.12, "Comments": "24ndsept Reading-108.12", "RolloverFlag": false, "ResetFlag": false, "ModifiedFlag": null, "InitialFlag": null, "DisabledFlag": null, "MeterDefinitionId": null, "MeterCode": null, "MeterId": 300100141395129, "MeterUsageCode": "ORA_ASSET", "AssetNumber": null, "AssetId": null }
Example 3 Request Body
This example includes the contents of the request body for a subscription meter in JSON format. You replace the request payload in the cURL command with the contents of the Example Request Body. The request payload specifies attribute values that the command will use in the record that it creates.
{ "MeterId": 789789898, "ReadingDate": "2020-11-02", "ReadingTypeCode": "ORA_ABSOLUTE", "MeterUsageCode": "ORA_CONTRACT_LINE", "ReadingValue": 20, "Comments": null }
Example 3 Response Body
This example includes the contents of the response body in JSON format:
{ "MeterReadingId": 123456789, "ReadingValue": 20, "ReadingDate": "2020-11-02T00:00:00+00:00", "ReadingTypeCode": "ORA_ABSOLUTE", "NetValue": 1015, "Comments": null, "RolloverFlag": false, "ResetFlag": false, "ModifiedFlag": null, "InitialFlag": null, "DisabledFlag": null, "MeterDefinitionId": null, "MeterCode": null, "MeterId": 789789898, "MeterUsageCode": "ORA_CONTRACT_LINE", "AssetNumber": null, "AssetId": null }
Example 4 Request Body
This example includes the contents of the request body for a subscription meter in JSON format. You replace the request payload in the cURL command with the contents of the Example Request Body. The request payload specifies attribute values that the command will use in the record to reset a meter. You replace the Reading Type Code with the value ORA_RESET and there is no need to pass a reading value as the reset value defined in the Meter Template will be used.
{ "AssetNumber": "ALM_WO_METER_1", "MeterCode": "METER_TEMP_CODE_ABS_ASC_1", "ReadingDate": "2021-02-05T12:00:00+00:00", "ReadingTypeCode": "ORA_RESET", "MeterUsageCode": "ORA_ASSET", "Comments": null }
Example 4 Response Body
This example includes the contents of the response body in JSON format:
{ "MeterReadingId": 300100544973893, "ReadingValue": 0, "ReadingDate": "2021-02-05T12:00:00+00:00", "ReadingTypeCode": "ORA_RESET", "NetValue": 17, "Comments": null, "RolloverFlag": false, "ResetFlag": true, "ModifiedFlag": null, "InitialFlag": null, "DisabledFlag": false, "MeterDefinitionId": null, "MeterCode": null, "MeterId": 300100544697266, "MeterUsageCode": "ORA_ASSET", "AssetNumber": null, "AssetId": null }