152 UDE-00001 to UDE-00054

UDE-00001: user requested cancel of current operation\n

Cause: User has requested a cancellation of current job.

Action: No action is needed.

UDE-00002: invalid username or password

Cause: An invalid username or password was specified.

Action: Retry with a valid username and password.

UDE-00003: all allowable logon attempts failed

Cause: Attempts were repeatedly made to log on with an invalid username or password.

Action: Shut down the utility, then restart and retry with a valid username and password.

UDE-00004: operation generated ORACLE error number

Cause: The operation unexpectedly produced the specified error. Refer to the description of that error for more information.

Action: Refer to the description of the reported error for possible actions.

UDE-00005: unexpected End-Of-File encountered while reading input\n

Cause: Encountered an End-Of-File while reading the user input.

Action: If input to export is being redirected, check the file for errors.

UDE-00006: failed to allocate memory of size number

Cause: Unable to allocate the necessary memory.

Action: Record the messages that follow and report this to Oracle Customer Support as an Export internal bug.

UDE-00007: attempt to free unallocated memory

Cause: An attempt was made to free memory that was not allocated.

Action: Contact Oracle Worldwide Support

UDE-00010: multiple job modes requested, string and string.

Cause: Multiple job modes were specified.

Action: Specify only one valid mode, then retry.

UDE-00011: parameter string is incompatible with parameter string

Cause: An invalid combination of parameters was specified.

Action: Refer to documentation for the set of valid modes, then retry.

UDE-00012: table mode exports only allow objects from one schema

Cause: Multiple schemas were selected for export.

Action: Retry export specifying only one schema.

UDE-00013: internal expdp error.

Cause: Fatal internal Data Pump client error.

Action: Contact Oracle Customer Support

UDE-00014: invalid value for parameter, 'string'.

Cause: Could not parse the specified parameter or parameter value.

Action: Refer to documentation for valid parameter values.

UDE-00015: invalid context or job state for parameter, 'string'.

Cause: Invalid job state or context for specified parameter.

Action: Refer to documentation for correct parameter usage.

UDE-00016: 'string' parameter requires a value.

Cause: Parameter was specified without a value.

Action: Refer to documentation for correct parameter usage.

UDE-00017: Data Pump job is already executing.

Cause: Incorrect Data Pump job state for requested operation.

Action: Refer to documentation for correct usage.

UDE-00018: Data Pump client is incompatible with database version string

Cause: The Export utility is at a higher version than the database version and is thereby incompatible.

Action: Use the same version of Export utility as the database.

UDE-00019: 'string' parameter list is too long.

Cause: Requested parameter list exceeds 4000 character maximum.

Action: Reduce the specified number of parameter values and rerun.

UDE-00020: Data Pump client is incompatible with Data Pump API.

Cause: The Export utility is at a higher version than the Data Pump server and is thereby incompatible.

Action: Use the same version of Export utility as the server.

UDE-00050: Unable to setup parameter processing.

Cause: An unexpected error occurred during parameter manager initialization.

Action: Record the messages that follow and report this to Oracle Customer Support as an Export internal bug.

UDE-00051: unable to set NLS_NUMERIC_CHARACTERS to required defaults.

Cause: Export was unable to set NLS_NUMERIC_CHARACTERS to '.,'

Action: Record the accompanying messages and report this as an Export internal error to Oracle customer support.

UDE-00052: incorrect Data Pump client for operation: string

Cause: Export client attempted to attach to import job.

Action: Use appropriate client when attaching to an existing job

UDE-00053: unrecognized client command 'string'

Cause: Invalid interactive client command.

Action: Refer to documentation for valid client commands.

UDE-00054: Deprecated Legacy Mode parameter 'string' specified at or on: string

Cause: The Legacy Mode parameter specified has no corresponding Data Pump mapping.

Action: Review the location referred to in the error message ( (either 'Command Line', 'Parameter File', or 'Environment Variable') and remove the parameter.