SET FRMLBOTTOMUP
The SET FRMLBOTTOMUP calculation command optimizes the calculation of complex formulas on sparse dimensions in large database outlines. This command tells Essbase to perform a bottom-up calculation on formulas that would otherwise require a top-down calculation.
You might want to turn on this setting when using the CALC ALL and CALC DIM commands to calculate the database.
Syntax
SET FRMLBOTTOMUP ON|OFF;Parameters
- ON
- 
                        Turns on the bottom-up sparse formula calculation method. 
- OFF
- 
                        Turns off the bottom-up sparse formula calculation method. The default setting is OFF. You can change the default behavior by setting the CALCOPTFRMLBOTTOMUP configuration setting to TRUE.
Notes
- 
                        For information on complex formulas and top-down calculations, see Optimizing Calculations. 
- 
                        Forcing a bottom-up calculation on a formula may produce results that are inconsistent with a top-down calculation if: - 
                              The formula contains complex functions (for example, range functions) 
- 
                              The formula's dependencies are not straightforward 
 
- 
                              
- 
                        Before using this command in a production environment, be sure to check the validity of calculation results produced when the command is enabled (set to ON). 
Example
SET FRMLBOTTOMUP ON;