2.2.1.1 About the RAID Storage Configuration

The local storage drives are configured in a RAID configuration.

Table 2-1 Disk Configurations for Database Servers on Exadata Two-Socket Exadata Systems

System Model RAID Controller Disk Configuration

Oracle Exadata X10M

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X9M-2

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X8M-2

MegaRAID SAS 9361-16i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X8-2

MegaRAID SAS 9361-16i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X7-2

MegaRAID SAS 9361-16i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X6-2

MegaRAID SAS 9361-8i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X5-2

MegaRAID SAS 9361-8i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X4-2

MegaRAID SAS 9261-8i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X3-2

MegaRAID SAS 9261-8i

4 disk drives in a RAID-5 configuration on each database server

Oracle Exadata X2-2

MegaRAID SAS 9261-8i

4 disk drives in a RAID-5 configuration on each database server

Table 2-2 Disk Configurations for Database Servers on Exadata Eight-Socket Exadata Systems

System Model RAID Controller Disk Configuration

Oracle Exadata X9M-8

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X8M-8

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X8-8

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X7-8

N/A

Two mirrored (RAID-1) NVMe flash drives in each database server

Oracle Exadata X5-8

MegaRAID SAS 9361-8i

8 disk drives in each database server with one virtual drive created across the RAID-5 set

Oracle Exadata X4-8

MegaRAID SAS 9261-8i

7 disk drives in each database server configured as one 6-disk RAID-5 with one global hot spare drive by default

Oracle Exadata X3-8

MegaRAID SAS 9261-8i

8 disk drives in each database server with one virtual drive created across the RAID-5 set