6.4.4.1.1 Controlling Fine-Grained Metric Collection
The metricFGCollIntvlInSec
attribute controls
fine-grained metric collection.
-
To enable fine-grained metric collection, you must set the collection interval to a value between 1 and 60 seconds.
For example:
CellCLI> ALTER CELL metricFGCollIntvlInSec=1
The
metricFGCollIntvlInSec
setting is related to the automatic upload frequency specified in themetricStreamIntvlInSec
attribute. When automatic metric upload and fine-grained collection are both enabled (metricStreamIntvlInSec>0
andmetricFGCollIntvlInSec>0
),metricStreamIntvlInSec
must be between 5 and 30 timesmetricFGCollIntvlInSec
. For example, ifmetricStreamIntvlInSec=60
, thenmetricFGCollIntvlInSec
must be between 2 and 12. -
To disable fine-grained metric collection on a server, set
metricFGCollIntvlInSec=0
.For example:
CellCLI> ALTER CELL metricFGCollIntvlInSec=0
Fine-grained metric collection can be disabled only when automatic metric upload is disabled (
metricStreamIntvlInSec=0
) or the automatic upload frequency is between 5 and 30 minutes (metricStreamIntvlInSec
is between 300 and 1800).
Parent topic: Using Fine-Grained Metrics