7.7.12.24 LIST PHYSICALDISK

Purpose

The LIST PHYSICALDISK command displays attributes for one or more physical disks determined by the specified attributes and filters.

Syntax

LIST PHYSICALDISK [ name |  attribute_filters ]  [attribute_list]  [DETAIL]

Usage Notes

  • You can use the DESCRIBE PHYSICALDISK command to view the complete list of PHYSICALDISK attributes.

  • When a physical disk is performing a power cycle, the status of the disk is included in the output. The status options are Normal-DiskPoweredOn, Normal-DiskPoweredOff, ProactiveFailure-DiskPoweredOn, and ProactiveFailure-DiskPoweredDown. If physical disk status shows as failed, perform a power cycle on the disk to verify the status of the physical disk.

Example 7-199 Listing Physical Disk Attributes

This example shows the LIST command with the PHYSICALDISK object, and the corresponding output.

CellCLI> LIST PHYSICALDISK
         20:0            K68DWJ          normal
         20:1            K7YXUJ          normal
         20:2            K7TYEJ          normal
         20:3            K7BJMJ          normal
         20:4            K5B4SM          normal
         20:5            KEBTDJ          normal
         20:6            K4URJJ          normal
         20:7            K5E1DM          normal
         20:8            K7VL6J          normal
         20:9            K7N5NJ          normal
         20:10           K7Z3KJ          normal
         20:11           K504ZM          normal
         FLASH_1_0       1030M03RK1      normal
         FLASH_1_1       1030M03RJN      normal
         FLASH_1_2       1030M03RJH      normal
         FLASH_1_3       1030M03RJD      normal
         FLASH_2_0       1027M03N6X      normal
         FLASH_2_1       1027M03NMN      normal
         FLASH_2_2       1027M03N6Y      normal
         FLASH_2_3       1027M03N6W      normal
         FLASH_4_0       1025M03EJ3      normal
         FLASH_4_1       1025M03EJ2      normal
         FLASH_4_2       1025M03EHU      normal
         FLASH_4_3       1025M03EKE      normal
         FLASH_5_0       1028M03QP8      normal
         FLASH_5_1       1028M03QNA      normal
         FLASH_5_2       1028M03QKU      normal
         FLASH_5_3       1028M03QHN      normal

CellCLI> LIST PHYSICALDISK 20:0 DETAIL
         name:                   20:0
         deviceId:               46
         deviceName:             /dev/sda
         diskType:               HardDisk
         enclosureDeviceId:      20
         errOtherCount:          0
         luns:                   0_0
         makeModel:              "HITACHI HUS1560SCSUN600G"
         physicalFirmware:       A8C0
         physicalInsertTime:     2017-07-27T07:03:00-04:00
         physicalInterface:      sas
         physicalSerial:         K68DWJ
         physicalSize:           558.9120712280273G
         slotNumber:             0
         status:                 normal

CellCLI> LIST PHYSICALDISK FLASH_5_3 DETAIL
         name:                   FLASH_5_3
         deviceName:             /dev/sdx
         diskType:               FlashDisk
         luns:                   5_3
         makeModel:              "Sun Flash Accelerator F20 PCIe Card"
         physicalFirmware:       D21Y
         physicalInsertTime:     2017-07-27T07:03:01-04:00
         physicalSerial:         1028M03QHN
         physicalSize:           22.8880615234375G
         slotNumber:             "PCI Slot: 5; FDOM: 3"
         status:                 normal