E Server Components

These sections describe Exadata Server X10M component names, status, and indicator states. The tables in this section identify the system components and describe the naming conventions applied to the components of Exadata Server X10M. Each section corresponds to an IPMI entity ID and lists sensors, indicators, and replaceable units related to that entity.

The tables contain the following fields:

  • Component Name – Shows the user-visible component name used in management interfaces to refer to a specific sensor, indicator, or replaceable unit. The IPMI name is a shortened form of the component name, and is indicated by the boldface portion of the component name.

  • IPMI Type – Indicates the type of sensor, indicator, or replaceable unit represented.

  • Description – Describes the particular component name reference.

  • Values – Defines the states of the sensor, indicator, or replaceable unit entity, and any specific units or values that are expected, if applicable.

This section includes information for the following server components.

System Chassis Components

The following table lists the system chassis components.

Table E-1 System Chassis Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS

FRU

Product information only

 

/SYS/UUID

FRU

Unique system ID

Derived from host MAC address. Used for PXE boot and licensing.

/SYS/ACPI

State sensor

Advanced Configuration and Power Interface

01h-ACPI_ON_WORKING

20h-ACPI_SOFT_OFF

/SYS/VPS

Threshold sensor

Virtual power consumption sensor

Watts

/SYS/VPS_CPUS

Threshold sensor

Virtual power sensor - CPU power consumption

Watts

/SYS/VPS_MEMORY

Threshold sensor

Virtual power sensor - memory power consumption

Watts

/SYS/VPS_FANS

Threshold sensor

Virtual power sensor - fan power consumption

Watts

/SYS/T_AMB

Threshold sensor

Ambient temperature on system motherboard

Degrees Celsius

/SYS/TEMP_FAULT

Indicator

Temperature Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: Chassis overtemp fault

/SYS/OK

Indicator

System OK LED

Color: Green

Location: Front and back panels

Off: Power is off.

Standby blink: Host is off, awaiting Power On.

Slow blink: Startup sequence initiated on host.

On: Host is booting OS or running the OS.

/SYS/SERVICE

Indicator

Fault-Service Required LED

Color: Amber

Location: Front and back panels

Off: Normal

On: Server requires service.

/SYS/LOCATE

Indicator

Locate Button/LED

Color: White

Location: Front and back panels

Off: Normal

Fast blink: Locate function is activated; self-extinguishes after 30 minutes.

/SYS/PS_FAULT

Indicator

Rear Power Supply Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: General power supply fault

/SYS/FAN_FAULT

Indicator

Top Fan Fault LED

Color: Amber

Location: Front panel

Off: Normal

On: General fan fault

/SYS/DO_NOT_SERVICE

Indicator

Do Not Service LED

Color: White

Location: Front panel

Off: Normal

On: Do not service this cell

 

Power Unit Components

The following table lists the power unit components.

Table E-2 Power Unit Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/PDB

FRU

Power distribution board FRU

 

/SYS/PS[0-1]

FRU

Power supply FRU

 

/SYS/PS[0-1]/PRSNT

Discrete sensor

Power supply is present. (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/PS[0-1]/STATE

State sensor

Power supply state sensor

Multistate, power supply sensor type, per IPMI

Presence detected

Failure detected

Predictive failure

Power supply input lost

Power supply input lost or out-of-range

Power supply input out-of-range

Configuration error

/SYS/PS[0-1]/P_IN

Threshold sensor

Input power draw

Watts

/SYS/PS[0-1]/P_OUT

Threshold sensor

Output power

Watts

/SYS/PS[0-1]/V_IN

Threshold sensor

Power supply input voltage

Volts

/SYS/PS[0-1]/V_12V

Threshold sensor

Power supply 12V output voltage

Volts

/SYS/PS[0-1]/V_12V_STBY

Threshold sensor

Power supply 12V standby output voltage

Volts

/SYS/PS[0-1]/T_IN

Threshold sensor

PSU input temperature

Degrees Celsius

/SYS/PS[0-1]/T_OUT

Threshold sensor

PSU output temperature

Degrees Celsius

Cooling Unit Components

The system has six 60-mm fan modules with two fans in each module. The following table lists the system cooling unit components.

Table E-3 Cooling Unit Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/FM[0-5]

FRU

Fan module FRU

 

/SYS/MB/FM[0-5]/F[0- x ]

FRU

Individual fan

 

/SYS/MB/FM[0-5] /PRSNT

Discrete sensor

Fan module is present.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/FM[0-5] /F[0-x]/TACH

Threshold sensor

Fan module fan speed

RPM

/SYS/MB/FM[0-5] /SERVICE

Indicator

Fan Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: Fan module was diagnosed as faulty.

Disk Backplane Components

The following table lists the disk backplane (DBP) components.

Table E-4 Disk Backplane Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP

FRU

Disk backplane FRU

 

/SYS/DBP/PRSNT

Discrete sensor

Disk backplane presence (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]

FRU

Hard disk drives (HDD)

 

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence(Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

State sensor

Hard disk drive state

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: HDD was diagnosed as failed

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to remove

Color: Blue

Location: HDD

Off: Normal

On: HDD is OK to remove

/SYS/DBP/HDD[0- x ]/NVME

FRU

NVMe drive FRU

 

/SYS/DBP/HDD[0- x ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/VREG_DBP_ERR

Discrete sensor

Disk backplane voltage regulator-down (VRD) error (Hidden)

01h-DEASSERTED

02h-ASSERTED

/SYS/VREG_USB_ERR

Discrete sensor

Universal Serial Bus (USB) VRD error (Hidden)

01h-DEASSERTED

02h-ASSERTED

Drive Components

The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.

Table E-5 Drive Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP/HDD[0- x ]

FRU

Hard disk drive FRU

From host

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

Discrete sensor

Writable multistate, slot/connector sensor type, per IPMI

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Hard disk drive Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: Hard disk drive was diagnosed as faulty.

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to Remove LED

Color: Blue

Location: HDD

Off: Normal

On: Drive is ready to remove.

/SYS/DBP/HDD[0- 3 ]/NVME

FRU

NVMe drive FRU

 

/SYS/DBP/HDD[0- 3 ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]

FRU

Internal M.2 SSD riser (2) FRU

 

/SYS/MB/SSDR[0-1]/PRSNT

Discrete sensor

Solid-state drive (SSD) riser presence (2 risers)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]

FRU

Internal SSD drive FRU

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/PRSNT

Discrete sensor

SSD drive presence (1 SSD per riser on 2U) (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/SSDR[0-1]/SSD[0-1]/STATE

State sensor

SSD drive state

04h-INSTALLED

20h-SLOT POWER OFF

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME

FRU

Internal SSD that is NVM Express FRU

 

/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME/PRSNT

Discrete sensor

Indicates the SSD is PCIe (NVMExpress)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

Processor Components

The following table lists the processor (CPU) components.

Table E-6 Processor Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/P[0- x ]

FRU

Host CPU FRU

 

/SYS/MB/P[0-1 ]/PRSNT

Discrete sensor

Host CPU is present.

01h-ENTITY_PRESENT

02h-ENTITY_ABSENT

/SYS/MB/P[0- x ]/SERVICE

Indicator

Host CPU Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: Processor was diagnosed as faulty.

Memory Device Components

The following table lists the memory device components.

Table E-7 Memory Device Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB/P[0- x ]/D[0-11]

FRU

Host CPU DIMM FRU

 

/SYS/MB/P[0-1 ]/D[0-11]/PRSNT

Discrete sensor

Host CPU DIMM is present.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/P[0- x ]/D[0-11]/SERVICE

Indicator

Host CPU DIMM Fault-Service Required LED

Color: Amber

Location: Motherboard

Off: Normal

On: DIMM was diagnosed as faulty.

/SYS/MB/P[0-1]/D[0-11]/TEMP

Discrete sensor

Host CPU DIMM temperature sensor (Hidden)

 

System Motherboard Components

The following table lists the system motherboard components.

Table E-8 System Motherboard Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB

FRU

General host system motherboard FRU

 

/SYS/MB/NET[0 ]

FRU

Host Ethernet FRU

 

/SYS/MB/PCIE[1-9]

FRU

PCIe slot

 

/SYS/MB/PCIE[1-9]/PRSNT

Discrete Sensor

PCIe slot is occupied.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/PCIE[1-9]/P_ENABLE_STATE

Indicator

PCIe slot power indicator

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/RISER[2-6]

FRU

PCIe Riser card FRU at Slot 2 and Slot 6 (Database Full Height card configuration)

 

/SYS/MB/RISER[2-6]/PRSNT

Discrete Sensor

PCIe Riser Card at Slot 2 or Slot 6 is present

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/RISER2/PCIE[2, 4]

FRU

PCIE Slot on RISER2

Slot 2 - x16 CEM slot

Slot 4 - x1 CEM slot for SMART NIC

 

/SYS//SYS/MB/RISER2/PCIE[2, 4]/PRSNT

Discrete Sensor

Option card inserted into PCIe Slots on Riser 2

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS//SYS/MB/RISER2/PCIE[2, 4]/P_ENABLE_STATE

State Sensor

PCIe slots on Riser 2 Power Enable State

02h-SLOT POWER ENABLED

01h-SLOT POWER DISABLED

/SYS//SYS/MB/RISER6/PCIE[6, 8]/PRSNT

Discrete Sensor

Option card inserted into PCIe Slots on Riser 6

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS//SYS/MB/RISER6/PCIE[6, 8]/P_ENABLE_STATE

State Sensor

PCIe slots on Riser 6 Power Enable State

02h-SLOT POWER ENABLED

01h-SLOT POWER DISABLED

/SYS/MB/ROT

FRU

Root of Trust FRU

Optional card is present in slot 1 (only supported slot)

 

/SYS//SYS/MB/ROT/PRSNT

Discrete Sensor

Root of Trust is Present

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/T_IN_ZONE[0-3]

Threshold sensor

Cooling zone input temperature sensor

Degrees Celsius

/SYS/MB/T_OUT_ZONE[0-3]

Threshold sensor

Cooling zone output temperature sensor

Degrees Celsius

/SYS/SP

FRU

Service processor FRU

 

/SYS/SP/OK

Indicator

 

SP OK LED

Color: Green

Location: Front panel

On: SP is operating.

Off: SP requires service.

/SYS/SP/NET[0-1]

FRU

SP Ethernet FRU

 

System Firmware Components

The following table lists the system firmware components.

Table E-9 System Firmware Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description

/SYS/MB/BIOS

FRU

BIOS FRU

/SYS/MB/CPLD

FRU

Motherboard complex programmable logic device (CPLD)/field programmable gate array (FPGA) firmware version